MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00068-019-01200-7

Медицинская библиотека · European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2019

Reduced complication rates for unstable trochanteric fractures managed with third-generation nails: Gamma 3 nail versus PFNA.

Bonnaire Felix, Lein Thomas, Fülling Tim, Bula Philipp

Сравнительное исследованиеСтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

INTRODUCTION

Third-generation nails for the management of unstable trochanteric fractures were evaluated with regard to outcomes.

PATIENTS AND

METHODS

A prospective observational study comparing the Gamma 3 nail and the Proximal Femoral Nail Antirotation (PFNA) in 106 unstable trochanteric fractures confirms the recently reported low intra- and postoperative complication rates from retrospective cohort studies.

RESULTS

Studies of same generations of both intramedullary nail systems did not reveal significant differences in intra- or postoperative complications. Intraoperative dislocation during nail insertion occurred 7 times for the Gamma nail and 9 times for the PFNA. The standard PFNA had to be exchanged intraoperatively for a shorter one on two occasions. Superficial wound healing disorders and hematoma requiring revision were observed in four patients in the Gamma 3 nail group and in three patients in the PFNA group. No deep infections were documented. Mechanical complications required revision in four patients (7.5%) after Gamma nailing and in two patients (3.8%) after PFNA. Postoperative rotation of the head-neck fragment was observed for the Gamma nail in three patients, not in the PFNA group. This was not statistically significant (p = 0.08). There were neither incidences of cut out without renewed trauma nor intraoperative fracture or postoperative femoral fracture. Nonunion affected 1 of 18 patients in late follow-up (p = 0.3) in the Gamma 3 nail group.

DISCUSSION: The Gamma 3 nail and the PFNA yielded comparable clinical results and significantly improved outcomes for unstable trochanteric fractures compared to older nail generations.

Для цитирования: Bonnaire Felix, Lein Thomas, Fülling Tim, Bula Philipp. Reduced complication rates for unstable trochanteric fractures managed with third-generation nails: Gamma 3 nail versus PFNA.. European journal of trauma and emergency surgery : official publication of the European Trauma Society. 2019. DOI: 10.1007/s00068-019-01200-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.