MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00068-022-02102-x

Медицинская библиотека · European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2022

Temporary spacer rod and plate technique: a novel intraoperative technical tip for minimizing the docking site malalignment during bone transport for bone loss in Gustilo IIIb open tibial fractures.

Dheenadhayalan Jayaramaraju, Nagashree Vasudeva, Devendra Agraharam, Jaganathan Thirumurugan, Rajasekaran Shanmuganathan

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Distraction osteogenesis is a safe and reliable option for managing bone defects of the tibia following major open fractures. Even though the Limb Reconstruction System (LRS) is a popular option, it may result in malalignment, necessitating an additional procedure to correct the alignment. The objective of the study is to assess the efficacy of a novel surgical technique in minimising malalignment.

METHODS

This was a retrospective cohort study conducted at a level 1 tertiary trauma centre consisting of 35 patients with primary bone loss following open tibia fractures. A uniplanar LRS frame was applied using a combined spacer rod with plate technique. Radiological assessment of docking site characteristics (translation, angulation) and functional assessment using ASAMI score was done.

RESULTS

The mean distraction regenerate length was 8.4 ± 3.45 cm. At the docking site, 18 patients did not have any deformity, 13 had a minor deformity of ≤ 5°, 2 had a moderate deformity of 6°-10° and 2 with a severe deformity > 10°. Circumferential docking was seen in 88.5% (31/35). According to the ASAMI functional scoring, 13 patients had excellent outcomes, 19 had good, one had fair, and two had poor outcomes. Six patients had pin tract infections, three had deep infections, and 17 had a delayed union. Our study had a lower incidence of malalignment compared to similar studies in the literature.

CONCLUSION

The use of this simple and economical intra-operative technique allowed for much higher precision in aligning the fracture ends, thus minimising the docking site malalignment.

LEVEL OF EVIDENCE: III.

LEVEL OF CLINICAL CARE: Level I Tertiary trauma centre.

Для цитирования: Dheenadhayalan Jayaramaraju, Nagashree Vasudeva, Devendra Agraharam, Jaganathan Thirumurugan, Rajasekaran Shanmuganathan. Temporary spacer rod and plate technique: a novel intraoperative technical tip for minimizing the docking site malalignment during bone transport for bone loss in Gustilo IIIb open tibial fractures.. European journal of trauma and emergency surgery : official publication of the European Trauma Society. 2022. DOI: 10.1007/s00068-022-02102-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.