MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.micpath.2024.106963

Медицинская библиотека · Microbial pathogenesis · 2024

Distribution of nontuberculous mycobacteria in dental unit waterlines: A potential health hazard in the dental office.

Vosooghi Kimia, Larypoor Mohaddeseh, Sakhaee Fatemeh, Ghazanfari Jajin Morteza, Moghaddam Sina, Samieefar Noosha, Rahbari Keramat Reza, Amiri Sabotki Mohsen, Fateh Abolfazl

СтатьяПеревод в очереди

Аннотация

BACKGROUND

It is essential to control the microbiology of dental unit water lines (DUWs) to prevent the spread of nontuberculous mycobacteria (NTM) and associated oral diseases. Therefore, the objective of this study was to quantify the presence of NTM in the water of 112 DUWs from dental centers and 57 DUWs from individual dental offices in Tehran, Iran.

METHODS

A total of 169 water samples were collected from DUWs. After filtration through a 0.45 μm membrane, the samples were decontaminated with 0.005 % cetylpyridinium chloride and then cultured on two Lowenstein-Jensen media, incubated at 25 °C and 37 °C for 8 weeks. Positive cultures for mycobacteria were analyzed using phenotypic tests, and the NTM species were identified through 16S rDNA, rpoB, and hsp65 genes analysis. Drug resistance was also assessed.

RESULTS

Of the total isolates, 38 (34.5 %) were classified as slow-growing mycobacteria (SGM), while 72 (65.5 %) were categorized as rapid-growing mycobacteria (RGM). NTM isolates were identified using molecular tests, including M. chelonae, M. abscessus, M. lentiflavum, M. mucogenicum, M. fortuitum, M. kansasii, M. simiae, M. gordonae, M. conceptionense, M. phocaicum, M. porcinum, and M. aurum. The NTM counts ranged from 50 to >500 CFU/500 mL across these 188 samples, with a median of 350 CFU/500 mL. Additionally, we reported two cases of intraoral infection caused by M. abscessus and M. chelonae, where the source of infection was traced to NTM-contaminated DUWs.

CONCLUSIONS

The study found that most DUWs contained water contaminated with NTM, posing a potential health risk to humans. This research underscores the necessity of stringent quality control and certification of DUW water, with particular emphasis on ensuring the absence of NTM.

Для цитирования: Vosooghi Kimia, Larypoor Mohaddeseh, Sakhaee Fatemeh, Ghazanfari Jajin Morteza, Moghaddam Sina, Samieefar Noosha, Rahbari Keramat Reza, Amiri Sabotki Mohsen, Fateh Abolfazl. Distribution of nontuberculous mycobacteria in dental unit waterlines: A potential health hazard in the dental office.. Microbial pathogenesis. 2024. DOI: 10.1016/j.micpath.2024.106963.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.