MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5152/j.aott.2025.24077

Медицинская библиотека · Acta orthopaedica et traumatologica turcica · 2025

Biomechanical comparison of rotator cuff repair techniques in osteoporotic conditions: testing a novel technique.

Eskara Hakan, Keskin Ahmet, Tatar Yasar, Gercek Nejla, Imren Yunus, Dedeoglu Suleyman Semih

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

Objective

This study aimed to compare the biomechanical characteristics of conventional transosseous equivalent (TOE) techniques with those of the novel free independent double-row medial fixation method, using rigid polyurethane (PU) foam blocks to simulate osteoporotic humerus bone.

Methods

In this biomechanical study, 4 groups were tested using rigid PU foam blocks with osteoporotic properties and bovine infraspinatus tendons to simulate the rotator cuff. Groups 1 and 2 employed conventional TOE techniques: medial row knotted repair and knotless repair, respectively. Groups 3 and 4 utilized the "free independent double-row medial fixation method," differing in the order of suture tying. Several biomechanical characteristic and pressure parameters were measured.

Results

Groups 3 (0.16 ± 0.04 MPa) and 4 (0.17 ± 0.05 MPa) achieved significantly higher initial contact pressure compared to standard TOE techniques (P=.039). While contact area (Group 3: 102.4 ± 55.0 mm², Group 4: 110.4 ± 37.2 mm²) and ultimate failure force (Group 3: 212.0 ± 26.5 N, Group 4: 214.7 ± 30.2 N) were relatively higher, the differences were not statistically significant (P=.135 and P=.3, respectively). The overall failure types included medial anchor pullout (40%) and suture/tendon stripping (32.5%), with no significant differences among groups (P=.260).

Conclusion

With superior contact pressure and comparable ultimate failure and contact area measurements, the novel independent double-row medial fixation technique may be a viable alternative to conventional TOE techniques for enhancing medial row stability in osteoporotic conditions. Level of Evidence: N/A.

Для цитирования: Eskara Hakan, Keskin Ahmet, Tatar Yasar, Gercek Nejla, Imren Yunus, Dedeoglu Suleyman Semih. Biomechanical comparison of rotator cuff repair techniques in osteoporotic conditions: testing a novel technique.. Acta orthopaedica et traumatologica turcica. 2025. DOI: 10.5152/j.aott.2025.24077.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.