Аннотация

OBJECTIVES

We report the radiographic and clinical outcome of patients treated with an angled blade plate (ABP) for hip fracture nonunion. We also provide a review of the literature on joint preserving treatment approaches to hip fracture nonunions.

DESIGN

Retrospective, case series.

SETTING

Tertiary academic hospital.

PATIENTS/

PARTICIPANTS

Three.

INTERVENTION: We treated three patients with varied hip fracture nonunions using a joint preserving approach with an ABP.

MAIN OUTCOME MEASUREMENTS: Radiographic union and clinical outcome.

RESULTS

All three patients achieved radiographic union, and were ambulating without pain at final follow-up.

CONCLUSIONS

The treatment approach to hip fracture nonunions is either restorative (joint preserving) or reconstructive (joint replacing). The primary restorative approach to nonunions around the hip consists of revision open reduction and internal fixation with or without bone grafting. Though a variety of implants and treatment techniques have demonstrated excellent success in this setting, revision open reduction and internal fixation with an ABP remains an efficacious implant selection in hip nonunion surgery.

Для цитирования: Lawrenz Joshua M, Marshall Danielle C, Patterson Brendan M. The utility of the angled blade plate in hip fracture nonunion treatment: A report of three cases and review of the literature.. OTA international : the open access journal of orthopaedic trauma. 2019. DOI: 10.1097/oi9.0000000000000041.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.