MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12903-022-02628-x

Медицинская библиотека · BMC oral health · 2022

Fracture resistance of prefabricated versus custom-made zirconia crowns after thermo-mechanical aging: an in-vitro study.

El Shahawy Osama Ibrahim, Azab Maha Moussa

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Prefabricated zirconia crowns for a young permanent molar is a child-friendly solution for restoring a permanent molar at a young age. This in-vitro study aimed to compare the fracture resistance of prefabricated versus custom-made permanent molar crowns.

METHODS

16 identical resin dies were fabricated to receive permanent molar zirconia crowns, dies were divided into 2 groups, 1) received perfricated crowns, 2) custom-made crowns. Thermo-dynamic cycling was performed to simulate 6 months in the oral cavity, Fracture resistance of each group was assessed by applying increasing load till fracture. Data were tested for normality using Shapiro-Wilk and Levene's tests. Data were analyzed using independent t test.

RESULTS

No statistically significant difference was found between fracture resistance of prefabricated and custom-made crowns (1793.54 ± 423.82) and (1987.38 ± 414.88) respectively. 3 crowns of the custom-made group fractured with the underlying die, versus zero dies fractured in the prefabricated group.

CONCLUSIONS

Prefabricated permanent molars zirconia crowns can perform as well as custom-made crowns for an adult in terms of fracture resistance, it is suitable for children and can withstand the occlusal forces of an adult.

Для цитирования: El Shahawy Osama Ibrahim, Azab Maha Moussa. Fracture resistance of prefabricated versus custom-made zirconia crowns after thermo-mechanical aging: an in-vitro study.. BMC oral health. 2022. DOI: 10.1186/s12903-022-02628-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.