MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00068-022-02082-y

Медицинская библиотека · European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2022

Anatomical analysis of different helical plate designs for proximal humeral shaft fracture fixation.

Pastor Torsten, Kastner Philipp, Souleiman Firas, Gehweiler Dominic, Migliorini Filippo, Link Björn-Christian, Beeres Frank J P, Babst Reto, Nebelung Sven, Ganse Bergita, Schoeneberg Carsten, Gueorguiev Boyko, Knobe Matthias

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

Helical plates are preferably used for proximal humeral shaft fracture fixation and potentially avoid radial nerve irritation.

AIMS: Safety of applying four different long plate designs (straight, 45°-, 90°-helical and ALPS) with MIPO technique as well as assessment and comparison of their distances to adjacent anatomical structures.

METHODS

MIPO was performed in 16 human cadaveric humeri using either a straight (group 1), a 45°-helical (group 2), a 90°-helical (group 3) plate, or an ALPS (group 4). Applying CT angiography, distances between brachial arteries and plates were evaluated. All specimens were dissected and distances to the axillary, radial and musculocutaneous nerve were evaluated.

RESULTS

No specimens demonstrated injuries of the anatomical structures at risk after MIPO with all investigated plate designs. Closest overall distance (mean (range); mm) between each plate and the radial nerve was 1 (1-3) in group 1, 7 (2-11) in group 2, 14 (7-25) in group 3 and 6 (3-8) in group 4. It was significantly bigger in group 3 and significantly smaller in group 1 compared to all other groups, p < 0.001. Closest overall distance between each plate and the musculocutaneous nerve was 16 (8-28) in group 1, 11 (7-18) in group 2, 3 (2-4) in group 3 and 6 (3-8) in group 4. It was significantly bigger in group 1 and significantly smaller in group 3 compared to all other groups, p < 0.001.

CONCLUSIONS

MIPO with 45°- and 90°-helical plates as well as with ALPS is safely feasible and demonstrates significantly bigger distances to the radial nerve compared to straight plates. However, the distances remain small and attention must be paid to the musculocutaneous nerve and the brachial artery when MIPO is applied using ALPS, 45°- and 90°-helical implants.

Для цитирования: Pastor Torsten, Kastner Philipp, Souleiman Firas, Gehweiler Dominic, Migliorini Filippo, Link Björn-Christian, Beeres Frank J P, Babst Reto, Nebelung Sven, Ganse Bergita, Schoeneberg Carsten, Gueorguiev Boyko, Knobe Matthias. Anatomical analysis of different helical plate designs for proximal humeral shaft fracture fixation.. European journal of trauma and emergency surgery : official publication of the European Trauma Society. 2022. DOI: 10.1007/s00068-022-02082-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.