m+Medelevator.RU
← Поиск публикаций
ACS omega · 2026

Alginate-Encapsulated HDES as a Green Sorbent for Elemental Preconcentration Prior to Determination by FAAS.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Müller Mateus Olivera, Araújo Mariana E M, Paiva Dos Santos Adriano Lucas, Costa Floriatan Santos, Grassi Marco Tadeu, Gonzalez Mario Henrique, Amaral Clarice D B

Аннотация

This study presents the development, characterization, and application of a new solid-phase extraction (SPE) sorbent for the preconcentration of Cd, Co, Cu, Fe, Mn, Ni, and Zn in water samples prior to analysis by flame atomic absorption spectrometry (FAAS). The sorbent was prepared by encapsulating hydrophobic deep eutectic solvents (HDES) in calcium alginate, a strategy that prevents HDES accumulation in FAAS and avoids nebulization and transport interferences. The developed method allows the analyte to be eluted into a clean aqueous phase (HNO3 3.5% v/v), containing negligible amounts of HDES. This is demonstrated by the excellent analytical figures of merit obtained, such as the correlation coefficient (R 2 > 0.9982) and precision (RSD <4.2%), and is further confirmed by the absence of HDES accumulation in the FAAS nebulization system. The encapsulation process involves Methol/Thymol (1:1 molar ratio) emulsified in a sodium alginate solution (10% v v-1 HDES content) droplet into a cross-linking agent (CaCl2 solution). Under optimized conditions, a 36 mL sample volume (pH 6.0 ± 0.1), 1 g of sorbent, 25 min extraction time, and desorption with 4 mL of 3.5% v v-1 HNO3 for 5 min were used. In these conditions, the method provided a 9-fold preconcentration factor, with recoveries between 81% and 109% for the seven monitored analytes. The accuracy was confirmed by analysis of real water samples, where concentrations of Cu and Zn ranged from 38 to 74 μg L-1 and 68 to 297 μg L-1, respectively, showing good agreement (91-109% recovery) with the independent ICP-OES procedure. Additionally, the sorbent demonstrated reusability, highlighting its potential as a low-cost, sustainable, and effective alternative for the trace elements determination in water samples by FAAS.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты