MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.otsr.2013.03.006

Медицинская библиотека · Orthopaedics & traumatology, surgery & research : OTSR · 2013

Outcomes at least 10 years after cemented PF® (Zimmer) total hip arthroplasty: 83 cases.

Aubault M, Druon J, Le Nail L, Rosset P

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Cementless total hip arthroplasty (TKA) is gaining ground over cemented TKA. The objective of this study was to assess survival rates of a cemented THA implant (PF(®), Zimmer), after at least 10 years and to assess changes in acetabular bone structure.

MATERIAL AND

METHODS

Eighty-three ceramic-on-polyethylene THA prostheses were implanted between 1998 and 2001. Clinical outcomes were assessed using the Harris hip score and Postel Merle d'Aubigné score. For each hip, radiographs were examined for acetabular radiolucent lines, geodes, and granulomas; in addition, changes in bone structure and trabeculae were assessed comparatively to the other hip and classified from no change to severe osteolysis. Changes in trabeculae served to assess the loads applied to the bone. Polyethylene wear was assessed using the Livermore method.

RESULTS

A single patient was lost to follow-up. At last follow-up, 16 patients had died and six were contacted and had not required revision surgery; the remaining 52 patients (59 THAs) were re-evaluated and none had evidence of loosening. The Harris hip score at last evaluation was 91.6 compared to 60.5 preoperatively. No hips had evidence of acetabular osteolysis. For two hips, the radiographs showed complete acetabular radiolucent lines less than 2mm in width, with no mobilisation. Trabecular distribution was homogeneous with no stress shielding. Mean annual rate of wear was 0.08mm. No instances of femoral component loosening were recorded; granulomas involving no more than five Gruën zones were seen in three cases.

DISCUSSION: This study confirms the reliability of cemented THA, with a 12-year survival rate of 98.3%, in keeping with earlier data. Thus, our results establish that cemented ceramic-on-polyethylene prostheses remain valid options for THA.

LEVEL OF EVIDENCE: IV.

Для цитирования: Aubault M, Druon J, Le Nail L, Rosset P. Outcomes at least 10 years after cemented PF® (Zimmer) total hip arthroplasty: 83 cases.. Orthopaedics & traumatology, surgery & research : OTSR. 2013. DOI: 10.1016/j.otsr.2013.03.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.