MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11926-013-0325-3

Медицинская библиотека · Current rheumatology reports · 2013

Anti-oxidation treatment of ultra high molecular weight polyethylene components to decrease periprosthetic osteolysis: evaluation of osteolytic and osteogenic properties of wear debris particles in a murine calvaria model.

Green Justin M, Hallab Nadim J, Liao Yen-Shuo, Narayan Venkat, Schwarz Edward M, Xie Chao

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАОбзорПеревод в очереди

Аннотация

Wear debris-induced osteolysis remains the greatest limitation of long-term success for total joint replacements with ultra-high molecular weight polyethylene (UHMWPE) bearings. To address oxidative degradation post-gamma irradiation, manufacturers are investigating the incorporation of antioxidants into PE resins. Similarly, larger molecular weight monomers have been developed to increase crosslinking and decrease wear debris, and ultimately osteolysis. However, the effects of modifying monomer size, crosslink density, and antioxidant incorporation on UHMWPE particle-induced osteoclastic bone resorption and coupled osteoblastic bone formation have never been tested. Here, we review the field of antioxidant-containing UHMWPE, and present an illustrative pilot study evaluating the osteolytic and osteogenic potential of wear debris generated from three chemically distinct particles (MARATHON®, XLK, and AOX™) as determined by a novel 3D micro-CT algorithm designed for the murine calvaria model. The results demonstrate an approach by which the potential osteoprotective effects of antioxidants in UHMWPE can be evaluated.

Для цитирования: Green Justin M, Hallab Nadim J, Liao Yen-Shuo, Narayan Venkat, Schwarz Edward M, Xie Chao. Anti-oxidation treatment of ultra high molecular weight polyethylene components to decrease periprosthetic osteolysis: evaluation of osteolytic and osteogenic properties of wear debris particles in a murine calvaria model.. Current rheumatology reports. 2013. DOI: 10.1007/s11926-013-0325-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.