DOI 10.7507/1002-1892.201808113
[Effectiveness analysis of distal radius microplate locking plate for treatment of displaced fracture of medial clavicle].
Аннотация
OBJECTIVE
To investigate and evaluate the effectiveness of the distal radius microplate locking plate for the treatment of displaced fracture of medial clavicle.
METHODS
Between January 2013 and June 2017, 18 cases of obvious displaced fracture of medial clavicle were treated with distal radius microlocking plate. There were 10 males and 8 females, with an average age of 51.4 years (range, 18-88 years). Causes of injury included traffic accident injury in 15 cases, heavy object injury in 3 cases; all of them were closed injury. According to Edinburgh classification, 15 cases were ⅠB1 type and 3 cases were ⅠB2 type. Fracture displacement was 12-21 mm (mean, 16.3 mm). The time from injury to operation was 3-7 days (mean, 4.3 days). After operation, the clinical healing and complications of fracture were observed, and shoulder function was evaluated according to Rockwood's scoring criteria.
RESULTS
No incisional infection, neurovascular injury, or other early complications occurred. All 18 patients were followed up 8-15 months (mean, 12 months). All fractures reached clinical osseous union, and the healing time was 8-24 weeks (mean, 16.6 weeks). Postoperative plate loosening occurred in 1 case, which was removed surgically, while other patients did not suffer from complications such as bone nonunion, displacement, internal fixator loosening, and loss of reduction. At last follow-up, according to Rockwood's scoring criteria, the results were excellent in 12 cases and good in 6 cases.
CONCLUSION
The distal radius microplate locking plate is effective for the treatment of displaced medial clavicle fracture, which has few complications, and is feasible for early functional exercise, and is helpful for the recovery of shoulder joint function.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.