MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00330-016-4671-1

Медицинская библиотека · European radiology · 2016

High-resolution ultrasound visualization of the recurrent motor branch of the median nerve: normal and first pathological findings.

Riegler Georg, Pivec Christopher, Platzgummer Hannes, Lieba-Samal Doris, Brugger Peter, Jengojan Suren, Vierhapper Martin, Bodner Gerd

Клинический случайСтатьяПеревод в очереди

Аннотация

PURPOSE: To evaluate in a prospective study the possibility of visualization and diagnostic assessment of the recurrent motor branch (RMB) of the median nerve with high-resolution ultrasound (HRUS).

MATERIALS AND

METHODS

HRUS with high-frequency probes (18-22 MhZ) was used to locate the RMB in eight fresh cadaveric hands. To verify correct identification, ink-marking and consecutive dissection were performed. Measurement of the RMB maximum transverse-diameter, an evaluation of the origin from the median nerve and its course in relation to the transverse carpal ligament, was performed in both hands of ten healthy volunteers (n = 20). Cases referred for HRUS examinations for suspected RMB lesions were also assessed.

RESULTS

The RMB was clearly visible in all anatomical specimens and all volunteers. Dissection confirmed HRUS findings in all anatomical specimens. Mean RMB diameter in volunteers was 0.7 mm ± 0.1 (range, 0.6-1). The RMB originated from the radial aspect in 11 (55%), central aspect in eight (40%) and ulnar aspect in one (5%) hand. Nineteen (95%) extraligamentous courses and one (5%) subligamentous course were detected. Three patients with visible RMB abnormalities on HRUS were identified.

CONCLUSION

HRUS is able to reliably visualize the RMB, its variations and pathologies.

KEY POINTS: • Ultrasound allows visualization of the recurrent motor branch of the median nerve. • Ultrasound may help clinicians to assess patients with recurrent motor branch pathologies. • Patient management may become more appropriate and targeted therapy could be improved.

Для цитирования: Riegler Georg, Pivec Christopher, Platzgummer Hannes, Lieba-Samal Doris, Brugger Peter, Jengojan Suren, Vierhapper Martin, Bodner Gerd. High-resolution ultrasound visualization of the recurrent motor branch of the median nerve: normal and first pathological findings.. European radiology. 2016. DOI: 10.1007/s00330-016-4671-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.