Vivaldi Antennas for Contactless Sensing of Implant Deflections and Stiffness for Orthopaedic Applications.

Wolynski Jakob G, Ilić Milan M, Notaroš Branislav M, Labus Kevin M, Puttlitz Christian M, McGilvray Kirk C

СтатьяПеревод в очереди

Аннотация

The implementation of novel coaxial dipole antennas has been shown to be a satisfactory diagnostic platform for the prediction of orthopaedic bone fracture healing outcomes. These techniques require mechanical deflection of implanted metallic hardware (i.e., rods and plates), which, when loaded, produce measurable changes in the resonant frequency of the adjacent antenna. Despite promising initial results, the coiled coaxial antenna design is limited by large antenna sizes and nonlinearity in the resonant frequency data. The purpose of this study was to develop two Vivaldi antennas (a.k.a., "standard" and "miniaturized") to address these challenges. Antenna behaviors were first computationally modeled prior to prototype fabrication. In subsequent benchtop tests, metallic plate segments were displaced from the prototype antennas via precision linear actuator while measuring resultant change in resonant frequency. Close agreement was observed between computational and benchtop results, where antennas were highly sensitive to small displacements of the metallic hardware, with sensitivity decreasing nonlinearly with increasing distance. Greater sensitivity was observed for the miniaturized design for both stainless steel and titanium implants. Additionally, these data demonstrated that by taking resonant frequency data during implant displacement and then again during antenna displacement from the same sample, via linear actuators, that "antenna calibration procedures" could be used to enable a clinically relevant quantification of fracture stiffness from the raw resonant frequency data. These improvements mitigate diagnostic challenges associated with nonlinear resonant frequency response seen in previous antenna designs.

Для цитирования: Wolynski Jakob G, Ilić Milan M, Notaroš Branislav M, Labus Kevin M, Puttlitz Christian M, McGilvray Kirk C. Vivaldi Antennas for Contactless Sensing of Implant Deflections and Stiffness for Orthopaedic Applications.. IEEE access : practical innovations, open solutions. 2021. DOI: 10.1109/access.2021.3137718.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.