BACKGROUND

Ventricular tachycardia (VT) and ventricular fibrillation (VF) are life-threatening conditions and can be refractory to conventional drug and device interventions. Stellate ganglion blockade (SGB) has been described as an adjunct, temporizing intervention in patients with refractory ventricular arrhythmia. We examined the association of SGB with VT/VF in a multicenter registry.

OBJECTIVES

This study examined the efficacy of SGB for treatment/temporization of refractory VT/VF.

METHODS

The authors present the first analysis from a multicenter registry of patients treated for refractory ventricular arrhythmia at a clinical site in the Czech Republic and the United States. Data were collected between 2016 and 2022. SGB was performed at the bedside by anesthesiologists and/or cardiologists. Outcomes of interest were VT/VF burden and defibrillations at 24 hours before and after SGB.

RESULTS

In total, there were 117 patients with refractory ventricular arrhythmias treated with SGB at Duke (n = 49) and the Institute for Clinical and Experimental Medicine (n = 68). The majority of patients were male (94.0%), were White (87.2%), and had an implantable cardioverter-defibrillator (70.1%). The most common etiology of heart disease was ischemic cardiomyopathy (52.1%), and monomorphic VT was the most common morphology (70.1%). Within 24 hours before SGB (0-24 hours), the median episodes of VT/VF were 7.5 (Q1-Q3: 3.0-27.0), and 24 hours after SGB, the median decreased to 1.0 (Q1-Q3: 0.0-4.5; P < 0.001). At 24 hours before SGB, the median defibrillation events were 2.0 (Q1-Q3: 0.0-8.0), and 24 hours after SGB, the median decreased to 0.0 (Q1-Q3: 0.0-1.0; P < 0.001).

CONCLUSIONS

In the largest cohort of patients with treatment-refractory ventricular arrhythmia, we demonstrate that SGB use was associated with a reduction in the ventricular arrhythmia burden and need for defibrillation therapy.

Для цитирования: Chouairi Fouad, Rajkumar Karuna, Benak Ales, Qadri Yawar, Piccini Jonathan P, Mathew Joseph, Ray Neil D, Toman Jakub, Kautzner Josef, Ganesh Arun, Sramko Marek, Fudim Marat. A Multicenter Study of Stellate Ganglion Block as a Temporizing Treatment for Refractory Ventricular Arrhythmias.. JACC. Clinical electrophysiology. 2024. DOI: 10.1016/j.jacep.2023.12.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.