MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/ortho.ijortho_476_17

Медицинская библиотека · Indian journal of orthopaedics · 2019

Augmentation Plate Fixation for Treating Subtrochanteric Fracture Nonunion.

Lo Yu Cheng, Su Yu Ping, Hsieh Cheng Pu, Huang Chun Hsiung

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The treatment of subtrochanteric fracture nonunion is challenging. Although revision with either an intramedullary or extramedullary device had been advocated with acceptable results, complications that require secondary procedures still arise. The use of an intramedullary device with augmentation plate fixation is a well-known approach for femoral or tibial diaphyseal nonunion. However, this approach has not previously been reported for subtrochanteric fracture nonunion.

MATERIALS AND

METHODS

A series of 21 cases of subtrochanteric fracture nonunion treated with an intramedullary device in combination with augmentation side plating were collected and retrospectively reviewed after an average of 18 months of followup. Fourteen patients with a prior well-fixed intramedullary device were treated with side plating and bone grafting. Seven patients underwent revision nailing in addition to side plating and bone grafting.

RESULTS

All fractures united well without major complication. The average time to union was 7.1 months.

CONCLUSION

The use of an intramedullary device with augmentation plate fixation is a reliable and decisive procedure for treating subtrochanteric fracture nonunion that produces satisfactory results with a low complication rate.

Для цитирования: Lo Yu Cheng, Su Yu Ping, Hsieh Cheng Pu, Huang Chun Hsiung. Augmentation Plate Fixation for Treating Subtrochanteric Fracture Nonunion.. Indian journal of orthopaedics. 2019. DOI: 10.4103/ortho.ijortho_476_17.