Design, Fabrication, and Accuracy of a Novel Noncovering Lock-Mechanism Bilateral Patient-Specific Drill Guide Template for Nondeformed and Deformed Thoracic Spines.

Ashouri-Sanjani Mehran, Mohammadi-Moghadam Shima, Azimi Parisa, Arjmand Navid

СтатьяПеревод в очереди

Аннотация

Background

Pedicle screw (PS) placement has been widely used in fusion surgeries on the thoracic spine. Achieving cost-effective yet accurate placements through nonradiation techniques remains challenging. Questions/Purposes: Novel noncovering lock-mechanism bilateral vertebra-specific drill guides for PS placement were designed/fabricated, and their accuracy for both nondeformed and deformed thoracic spines was tested.

Methods

One nondeformed and 1 severe scoliosis human thoracic spine underwent computed tomographic (CT) scanning, and 2 identical proportions of each were 3-dimensional (3D) printed. Pedicle-specific optimal (no perforation) drilling trajectories were determined on the CT images based on the entry point/orientation/diameter/length of each PS. Vertebra-specific templates were designed and 3D printed, assuring minimal yet firm contacts with the vertebrae through a noncovering lock mechanism. One model of each patient was drilled using the freehand and one using the template guides (96 pedicle drillings). Postoperative CT scans from the models with the inserted PSs were obtained and superimposed on the preoperative planned models to evaluate deviations of the PSs.

Results

All templates fitted their corresponding vertebra during the simulated operations. As compared with the freehand approach, PS placement deviations from their preplanned positions were significantly reduced: for the nonscoliosis model, from 2.4 to 0.9 mm for the entry point, 5.0° to 3.3° for the transverse plane angle, 7.1° to 2.2° for the sagittal plane angle, and 8.5° to 4.1° for the 3D angle, improving the success rate from 71.7% to 93.5%.

Conclusions

These guides are valuable, as the accurate PS trajectory could be customized preoperatively to match the patients' unique anatomy. In vivo studies will be required to validate this approach.

Для цитирования: Ashouri-Sanjani Mehran, Mohammadi-Moghadam Shima, Azimi Parisa, Arjmand Navid. Design, Fabrication, and Accuracy of a Novel Noncovering Lock-Mechanism Bilateral Patient-Specific Drill Guide Template for Nondeformed and Deformed Thoracic Spines.. HSS journal : the musculoskeletal journal of Hospital for Special Surgery. 2021. DOI: 10.1177/1556331621996331.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.