MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0300060519835334

Медицинская библиотека · The Journal of international medical research · 2019

Sliding bone graft combined with double locking plate fixation for the treatment of femoral shaft nonunion.

Xing Wenzhao, Pan Zhenhua, Sun Lei, Sun Liang, Zhang Chunpu, Zhang Zhiguo, Feng Wenling, Liu Changcheng

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

The aim of this study was to describe and evaluate a novel method of sliding bone graft combined with double locking plate fixation in treating femoral shaft nonunion.

METHODS

Clinical data from patients with femoral shaft nonunion that was treated with sliding bone grafts combined with double locking plate fixation were retrospectively collected. Data included duration of surgery, blood loss, union rate, time to union and possible complications.

RESULTS

Twenty-five patients included in the study were followed for a mean duration of 16.6 ± 2.6 months (range, 12-22 months). All of the fractures (100%) achieved bony union. Mean time to union was 6.0 ± 1.0 months (range, 4-8 months). No infections or medullary cavity occlusions were observed.

CONCLUSIONS

Sliding bone graft combined with double locking plate fixation was shown to be a safe, effective, and convenient surgical option for the treatment of nonunion, due to its high union rates with no complications. Further studies with larger sample sizes and longer-term follow-up are warranted.

Для цитирования: Xing Wenzhao, Pan Zhenhua, Sun Lei, Sun Liang, Zhang Chunpu, Zhang Zhiguo, Feng Wenling, Liu Changcheng. Sliding bone graft combined with double locking plate fixation for the treatment of femoral shaft nonunion.. The Journal of international medical research. 2019. DOI: 10.1177/0300060519835334.