MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3233/bme-221392

Медицинская библиотека · Bio-medical materials and engineering · 2023

An in vivo preclinical study assessing biocompatibility of Pd-based bulk metallic glass.

Witek Lukasz, Vivekanand Nayak Vasudev, Rodriguez Colon Ricardo, Torroni Andrea, Demetriou Marios D, Coelho Paulo G

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The bulk metallic glass (BMG), Pd79Ag3.5P6Si9.5Ge2, has a high fracture toughness and has been found to accommodate post-yield stress, unlike most other BMG. Moreover, due to its greater noble gas composition it has a intrinsic corrosion resistance, ideal for dental and orthopedic implants.

OBJECTIVE

This present study aimed to evaluate the in vivo application of Pd79Ag3.5P6Si9.5Ge2 in a large translational sheep model to assess its efficacy to be utilized as an endosteal device.

METHODS

Twelve implants in the form of cylindrical rods (3 mm in diameter) were produced through rapid quenching. Each sheep (n = 12) received one osteotomy in the mandibular region using rotary instrumentation, which was filled with Pd79Ag3.5P6Si9.5Ge2. After 6- and 24-weeks the animals were euthanized, and samples collected en bloc to conduct histomorphometric analysis. The degree of osseointegration were assessed through bone-to-implant contact (BIC).

RESULTS

All samples revealed favorable BIC along with with fibrous connective tissue layers at both 6- and 24-weeks. Bone along with interfacial remodeling was observed in proximity with the metallic glass surface at 6 weeks with higher degrees of bone organization being observed at the later healing time, 24 weeks.

CONCLUSIONS

The synthesized BMG, given its unique combination of toughness and strength, revealed potential to serve as an alternative to commonly used Ti alloys.

Для цитирования: Witek Lukasz, Vivekanand Nayak Vasudev, Rodriguez Colon Ricardo, Torroni Andrea, Demetriou Marios D, Coelho Paulo G. An in vivo preclinical study assessing biocompatibility of Pd-based bulk metallic glass.. Bio-medical materials and engineering. 2023. DOI: 10.3233/bme-221392.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.