Three-dimensional-guided navigation percutaneous screw fixation of fragility fractures of the pelvis.
Аннотация
BACKGROUND
Three-dimensional (3D)-guided navigation percutaneous screw fixation of pelvi-acetabular fractures has been reported in patients with high-energy trauma. Its use in fragility fractures of the pelvis is expanding and its results are promising.
METHODS
We report a series of 17 consecutive patients with fragility fractures of the pelvis treated with 3D-guided navigation percutaneous screw fixation from 2016 to 2017. Percutaneous screw trajectories were planned preoperatively for the majority of patients. Closed reduction was performed prior to fixation in grossly displaced fractures.
RESULTS
The mean time to surgery was 8.6 ± 2.4 days, and the mean intraoperative blood loss was 94.1 ± 26.6 mL. One early surgical complication occurred involving an infected pelvic external fixator iliac pin track site, and there were no cases of neurological deficits after fixation. In total, 7 of the 14 patients had screw backout, and the mean backout distance was 8.3 ± 4.4 mm. Cortical perforation was seen in one patient involving an anterior column screw by 5.7 mm; 14 patients were followed up for a mean of 18.7 ± 2.8 months; 13 patients achieved complete fracture union, and 1 patient had a fracture non-union. Premorbid ambulatory function was restored in 8 of the 14 patients. The mean visual analogue scale for pain severity at follow-up was 0.36 ± 0.50. There were no cases of 30-day and 1-year mortality.
CONCLUSION
3D-guided navigation percutaneous screw fixation is a safe, precise, and effective surgical technique for managing fragility fractures of the pelvis.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.