MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4085/1062-6050-52.2.09

Медицинская библиотека · Journal of athletic training · 2017

Phototherapy for Improvement of Performance and Exercise Recovery: Comparison of 3 Commercially Available Devices.

De Marchi Thiago, Schmitt Vinicius Mazzochi, Danúbia da Silva Fabro Carla, da Silva Larissa Lopes, Sene Juliane, Tairova Olga, Salvador Mirian

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

CONTEXT: Recent studies suggest the prophylactic use of low-powered laser/light has ergogenic effects on athletic performance and postactivity recovery. Manufacturers of high-powered lasers/light devices claim that these can produce the same clinical benefits with increased power and decreased irradiation time; however, research with high-powered lasers is lacking.

OBJECTIVE

To evaluate the magnitude of observed phototherapeutic effects with 3 commercially available devices.

DESIGN

Randomized double-blind placebo-controlled study.

SETTING

Laboratory.

PATIENTS OR OTHER

PARTICIPANTS

Forty healthy untrained male participants.

INTERVENTION(S): Participants were randomized into 4 groups: placebo, high-powered continuous laser/light, low-powered continuous laser/light, or low-powered pulsed laser/light (comprising both lasers and light-emitting diodes). A single dose of 180 J or placebo was applied to the quadriceps.

MAIN OUTCOME MEASURE(S): Maximum voluntary contraction, delayed-onset muscle soreness (DOMS), and creatine kinase (CK) activity from baseline to 96 hours after the eccentric exercise protocol.

RESULTS

Maximum voluntary contraction was maintained in the low-powered pulsed laser/light group compared with placebo and high-powered continuous laser/light groups in all time points (P < .05). Low-powered pulsed laser/light demonstrated less DOMS than all groups at all time points (P < .05). High-powered continuous laser/light did not demonstrate any positive effects on maximum voluntary contraction, CK activity, or DOMS compared with any group at any time point. Creatine kinase activity was decreased in low-powered pulsed laser/light compared with placebo (P < .05) and high-powered continuous laser/light (P < .05) at all time points. High-powered continuous laser/light resulted in increased CK activity compared with placebo from 1 to 24 hours (P < .05).

CONCLUSIONS

Low-powered pulsed laser/light demonstrated better results than either low-powered continuous laser/light or high-powered continuous laser/light in all outcome measures when compared with placebo. The increase in CK activity using the high-powered continuous laser/light compared with placebo warrants further research to investigate its effect on other factors related to muscle damage.

Для цитирования: De Marchi Thiago, Schmitt Vinicius Mazzochi, Danúbia da Silva Fabro Carla, da Silva Larissa Lopes, Sene Juliane, Tairova Olga, Salvador Mirian. Phototherapy for Improvement of Performance and Exercise Recovery: Comparison of 3 Commercially Available Devices.. Journal of athletic training. 2017. DOI: 10.4085/1062-6050-52.2.09.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.