MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5507/bp.2012.063

Медицинская библиотека · Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia · 2012

Advantages and disadvantages of ceramic on ceramic total hip arthroplasty: a review.

Gallo Jiri, Goodman Stuart Barry, Lostak Jiri, Janout Martin

СтатьяПоддержка исследования: вне правительства СШАОбзорПеревод в очереди

Аннотация

BACKGROUND

Ceramic on ceramic (COC) total hip arthroplasty (THA) was developed to reduce wear debris and accordingly, the occurrence of osteolysis and aseptic loosening especially in younger patients. Based on the excellent tribological behavior of current COC bearings and the relatively low biological activity of ceramic particles, significant improvement in survivorship of these implants is expected.

METHODS

We used manual search to identify all relevant studies reporting clinical data on COC THAs in PubMed. The objective was to determine whether current COC THA offers a better clinical outcome and survivorship than non-COC THA.

RESULTS

Studies with early generation ceramic bearings yielded 68% to 84% mean survivorship at 20 years follow-up which is comparable with the survivorship of non-COC THAs. Studies on current ceramic bearings report a 10-year revision-free interval of 92% to 99%. These outcomes are comparable to the survivorship of the best non-COC THAs. However, there are still concerns regarding fracture of sandwich ceramic liners, squeaking, and impingement of the femoral neck on the rim of the ceramic liner leading to chipping, especially in younger and physically active patients.

CONCLUSION

Current COC THA leads to equivalent but not improved survivorship at 10 years follow-up in comparison to the best non-COC THA. Based on this review, we recommend that surgeons weigh the potential advantages and disadvantages of current COC THA in comparison to other bearing surfaces when considering young very active patients who are candidates for THA.

Для цитирования: Gallo Jiri, Goodman Stuart Barry, Lostak Jiri, Janout Martin. Advantages and disadvantages of ceramic on ceramic total hip arthroplasty: a review.. Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia. 2012. DOI: 10.5507/bp.2012.063.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.