MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12891-022-05482-8

Медицинская библиотека · BMC musculoskeletal disorders · 2022

Comparison of clinical outcomes of three internal fixation techniques in the treatment of olecranon fracture: a retrospective clinical study.

Qi Hongfei, Li Zhong, Lu Yao, Ma Teng, Ji Shuai, Du Bing, Li Ming, Huang Qiang, Zhang Kun, Yang Yanling

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

The application of double plating in olecranon fractures is becoming increasingly widespread. There is no research comparing this technique with traditional tension band wiring (TBW) and the single plate technique. The purpose of this study was to compare the efficacy of three fixation techniques in olecranon fractures.

MATERIALS AND

METHODS

From March 2016 to May 2020, we collected the clinical data of 95 patients with olecranon fractures who underwent surgical treatment. Thirty-five patients received TBW surgery (TBW Group), 32 patients received a 3.5 mm locking compression plate (LCP, 3.5 mm LCP Group), and 28 patients received double mini-locking plate treatment (DP Group). The operation time, fracture union time, time of return to work, range of motion (ROM), soft tissue stimulation to remove internal fixation, and patient-related functional results (the Weseley score, Mayo Elbow Performance Score [MEPS], and Disabilities of Arm, Shoulder and Hand Score [DASH]) were recorded. The clinical results and complications of the three internal fixation techniques were compared.

RESULTS

The average follow-up time was 15.011.82 months (12-18 months). All patients' fractures healed by first intention. There were no statistically significant differences in the operation time, fracture union time, ROM, Weseley score, MEPS or DASH scores of the three groups of patients. The postoperative return time for patients in the TBW group was 10.002.15 weeks, the 3.5 mm LCP group was 9.561.93 weeks, and the DP group was 8.432.38 weeks (P = 0.014); 12 patients in the TBW group required removal of plant due to soft tissue stimulation, the 3.5 mm LCP group had 8 cases, and the DP group had 2 cases (P = 0.038).

CONCLUSION

The postoperative clinical results and elbow joint function of patients with olecranon fractures fixed by tension band wiring, 3.5 mm LCP and double mini-locking plate are similar, which indicates that double-plate technology can be used as an alternative to the two groups of traditional techniques. In addition, double-plate technology also helps patients return to work earlier and has a lower incidence of soft tissue stimulation.

Для цитирования: Qi Hongfei, Li Zhong, Lu Yao, Ma Teng, Ji Shuai, Du Bing, Li Ming, Huang Qiang, Zhang Kun, Yang Yanling. Comparison of clinical outcomes of three internal fixation techniques in the treatment of olecranon fracture: a retrospective clinical study.. BMC musculoskeletal disorders. 2022. DOI: 10.1186/s12891-022-05482-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.