MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00590-022-03298-9

Медицинская библиотека · European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2022

Minimum 2-year results of the second-generation CFR-PEEK locking plate on the proximal humeral fracture.

Dey Hazra Rony-Orijit, Szewczyk Karol, Ellwein Alexander, Blach Robert, Jensen Gunnar, Kühnapfel Andreas, Lill Helmut, Warnhoff Mara

СтатьяПеревод в очереди

Аннотация

PURPOSE: The aim of this study was to analyse and compare the 24-month range of motion results of patients treated with CFR-PEEK2 versus conventional titanium plate osteosyntheses (TAL-P). We hypothesized similar clinical outcomes but a better range of motion in the CFR-PEEK2 group than the TAL-P group in the 2-year follow-up.

METHODS

This retrospective study analysing prospectively collected data included all patients that presented with a PHF and were treated with CFR-PEEK2 between November 2016 and April 2018. Follow-up was performed after a minimum of 24 months, evaluating the functional degree of movement functional scores, including the Subjective Shoulder Value (SSV) as well as an age- and sex-adapted Constant-Murley score (CMS). The 2-year results were compared to the results of a matched pair group comprising patients that were treated with TAL-P during the same period.

RESULTS

Of the 35 patients included (mean age: 61.2 [18-78] years), 30 (86%) patients completed the 24-month follow-up in the CFR-PEEK2-group. After 24 months, the mean CMS was 89.9 points (pt) (44.5-100 pt) and the mean SSV was 86.7% (35-100%). Compared to the matched-pair TAL-P cohort, the 24-month follow-up showed similar results (CMS: 88.6 pt. (40.5-100 pt.) [p = 0.9]; SSV: 76% (30-100%) [p = 0.05]). However, significantly better degrees of forward flexion and internal rotation as well as a better range of motion in abduction was recorded in patients treated with CFR-PEEK2 plates than TAL-P.

CONCLUSION

At the 24-month follow-up, patients who received treatment with CFR-PEEK2 compared to those that received TAL-P showed enhanced range of motion whilst having similar clinical scores.

Для цитирования: Dey Hazra Rony-Orijit, Szewczyk Karol, Ellwein Alexander, Blach Robert, Jensen Gunnar, Kühnapfel Andreas, Lill Helmut, Warnhoff Mara. Minimum 2-year results of the second-generation CFR-PEEK locking plate on the proximal humeral fracture.. European journal of orthopaedic surgery & traumatology : orthopedie traumatologie. 2022. DOI: 10.1007/s00590-022-03298-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.