MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11095-010-0248-x

Медицинская библиотека · Pharmaceutical research · 2010

High loading of gentamicin in bioadhesive PVM/MA nanostructured microparticles using compressed carbon-dioxide.

Elizondo Elisa, Sala Santiago, Imbuluzqueta Edurne, González David, Blanco-Prieto María J, Gamazo Carlos, Ventosa Nora, Veciana Jaume

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To investigate, for the first time, the viability of compressed antisolvent methodologies for the preparation of drug-loaded particles of the biodegradable and bioadhesive polymer poly (methyl vinyl ether-co-maleic anhydride) (PVM/MA), utilizing gentamicin (Gm) as a model drug.

METHODS

Precipitation with a Compressed Antisolvent (PCA) method was used for the preparation of PVM/MA particles loaded with gentamicin. Before encapsulation, gentamicin was modified into a hydrophobic complex, GmAOT, by exchanging its sulphate ions with an anionic surfactant. GmAOT:PVM/MA composites were fully characterized in terms of size, morphology, composition, drug distribution, phase composition, in vitro activity and drug release.

RESULTS

Homogeneous nanostructured microparticles of PVM/MA loaded with high and uniformly distributed quantities of GmAOT were obtained by PCA. The drug loading factors could be tuned at will, improving up to ten times the loadings obtained by other precipitation techniques. Gentamicin retained its bioactivity after being processed, and, according to its release profiles, after an initial burst it experienced a sustained release over 30 days.

CONCLUSIONS

Compressed antisolvent methods are suitable technologies for the one-step preparation of highly loaded nanostructured PVM/MA matrices with promising application in the delivery of low bioavailable drugs.

Для цитирования: Elizondo Elisa, Sala Santiago, Imbuluzqueta Edurne, González David, Blanco-Prieto María J, Gamazo Carlos, Ventosa Nora, Veciana Jaume. High loading of gentamicin in bioadhesive PVM/MA nanostructured microparticles using compressed carbon-dioxide.. Pharmaceutical research. 2010. DOI: 10.1007/s11095-010-0248-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.