MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00264-022-05425-x

Медицинская библиотека · International orthopaedics · 2022

Lateral malleolar fractures Weber Type A and B: does percutaneous intramedullary screw confer a solid alternative to the traditional neutralization plate?

Zawam Sherif Hamdy, Mabrouk Mohamed Goda, El-Desouky Mahmoud Ahmed

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To compare the clinical results, complication rates, and radiographic outcome between both methods of fixation of lateral malleolar fractures: lateral neutralization plates and intramedullary fully threaded screws.

PATIENTS AND

METHODS

This prospective case series study involved 73 patients with fractured lateral malleolus of type A, B according to Weber classification, to whom internal fixation was performed by either lateral plate and screws construct (Group A) or intramedullary screw (Group B). All patients were followed up for 12 months at least, with an average follow-up time of 12.7 months.

RESULTS

There was no significant difference in the functional outcome score between both groups. The intramedullary screw group had a significantly shorter operative time and time to full union (P<0.001 and =0.006 respectively). There was a relatively higher accuracy of reduction with the plate fixation group, but it was statistically insignificant. There was a relatively fewer complication rate with the use of intramedullary screw fixation compared to plate fixation.

CONCLUSION

The use of intramedullary fixation is a good alternative for plate fixation in low fibular fractures (Weber A and B). Although plate fixation provides an optimal anatomic reconstruction of the fractures, intramedullary fixation may have a lower risk of complications.

Для цитирования: Zawam Sherif Hamdy, Mabrouk Mohamed Goda, El-Desouky Mahmoud Ahmed. Lateral malleolar fractures Weber Type A and B: does percutaneous intramedullary screw confer a solid alternative to the traditional neutralization plate?. International orthopaedics. 2022. DOI: 10.1007/s00264-022-05425-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.