DOI 10.1016/j.injury.2018.09.045
Re-fractures after periprosthetic femoral fracture: A difficult to treat growing evidence.
Аннотация
INTRODUCTION
Periprosthetic fractures are increasing. The treatment is mostly surgical, but it has a high complication rate. Re-fracture and non-union with implant failure are the more frequent complications. Those complications are difficult to treat and can lead to severe disability. The purpose of this study is to determine the clinical results of periprosthetic femoral re-fracture treatment.
MATERIALS AND
METHODS
Twenty patients were treated for femoral re-fractures (17 women, 3 men). The mean age and follow-up are 75.7 years (46-95) and 6.15 years (0.4-15) respectively. The diagnosis of new periprosthetic fracture according to Vancouver classification were: 3 type A, 5 type B1, 1 type B2, 2 B3, 8 type C; 1 Lewis-Rorabeck type II. Patients were followed-up clinically, with a Harris Hip Score, and radiologically at 2, 4, 6, 12 months, and then annually.
RESULTS
All patients healed except for two cases in which an infection occurred. Two cases, treated with plate osteosynthesis, had a malunion in varus. Six patients died for unrelated reasons after fracture healing. One patient was excluded because of a follow-up shorter than 12 months. In 16 cases (84%) a Trendelenburg gait or the use of aids for walking has been necessary. At final follow-up the mean HHS was 65 (range 45-82). Fractures treatment differed depending on the type of the fracture, prosthesis stability and bone loss. Tension band wiring, long plate fixation, revision with a long stem with cables or a sandwich technique (two plates or one plate plus one strut graft) have been performed according to fracture type.
CONCLUSIONS
Re-fractures and non-union with implant failure are common after periprosthetic fracture treatment. Infection and malunion are the main complications of their treatment. Residual limping with the necessity of aids even after fracture healing is often present. The choice of a correct surgical strategy is essential to minimize the risk of new complications and ensure the highest possibility to heal. The most important factor is to achieve a good stability, a reasonable vital environment and don't leave new areas of lower resistance uncovered. Poor functional outcome has to be expected especially in refracture after a revision surgery.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.