[Augmentation in the treatment of proximal humeral and femoral fractures].

van Veelen Nicole M, Beeres Frank Jp, Link Björn-Christian, Babst Reto

СтатьяОбзорПеревод в очереди

Аннотация

BACKGROUND

Proximal humeral and trochanteric femoral fractures in older patients are typically caused by low-energy trauma and are therefore often associated with osteoporosis. The treatment of such fragility fractures can be difficult as implant purchase is reduced in osteoporotic bone. By augmenting the fixation with cement the contact surface between implant and bone can be increased, which improves the stability of the osteosynthesis.

OBJECTIVE

This article describes the operative technique for the augmentation of trochanteric femoral fractures treated with the Trochanteric Fixation Nail-Advanced (TFNA, DePuy Synthes, Oberdorf BL, Switzerland) and proximal humeral fractures stabilized with a PHILOS plate (DePuy Synthes). Furthermore, the evidence for the augmentation of these two fracture types is elucidated.

RESULTS

Biomechanical studies could show an improved stability of the osteosynthesis after successful augmentation for both fracture types. The current evidence also indicates a clinical reduction of fixation failure. Whether the augmentation has an influence on the functional result could so far not yet clearly be proven.

CONCLUSION

Augmentation seems to be a safe and valuable addition to available treatment options especially for patients with fragility fractures.

Для цитирования: van Veelen Nicole M, Beeres Frank Jp, Link Björn-Christian, Babst Reto. [Augmentation in the treatment of proximal humeral and femoral fractures].. Unfallchirurgie (Heidelberg, Germany). 2022. DOI: 10.1007/s00113-022-01172-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.