MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5301/hip.2012.9075

Медицинская библиотека · Hip international : the journal of clinical and experimental research on hip pathology and therapy · 2012

Superior 11-year survival but higher polyethylene wear of hydroxyapatite-coated Mallory-Head cups.

Gottliebsen Martin, Rahbek Ole, Ottosen Per F, Søballe Kjeld, Stilling Maiken

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Hydroxyapatite (HA) coating of implant surfaces is believed to improve longevity of uncemented total hip arthroplasty (THA). However; it is speculated that HA particles may cause third body wear of the polyethylene (PE) liner with subsequent osteolysis and aseptic loosening of implants. We performed a retrospective comparison of two patient populations with cementless Mallory-Head acetabular components. The patients were identified in the Danish hip arthroplasty Registry (DHR); 77 patients had HA-coated cups and 73 patients had non-HA coated cups. Anteroposterior (AP) radiographs were analysed for PE wear, osteolysis was quantified and survival of the acetabular components was compared. The mean follow-up was 11 years. There were no cup revisions in the HA group and 7 cup revisions in the non-HA group (P<0.01). The reason for revision in all cases was aseptic loosening of both stem and cup. The amount of osteolysis was significantly increased around cups in the non-HA group. The two-dimensional linear PE wear-rate of 0.18 mm/year was higher (P<0.001) in the group with HA coated cups compared with 0.12 mm/year in the group with non-HA coated cups. The mean age was lower (P=0.001) in the HA group (57 years) compared with the non-HA group (63 years). After 11.1 years of follow-up non-HA coated cups had a higher revision rate. Increased PE wear with HA-coated cups did not have a negative influence on the revision rate, but may result in a need for revision surgery over time.

Для цитирования: Gottliebsen Martin, Rahbek Ole, Ottosen Per F, Søballe Kjeld, Stilling Maiken. Superior 11-year survival but higher polyethylene wear of hydroxyapatite-coated Mallory-Head cups.. Hip international : the journal of clinical and experimental research on hip pathology and therapy. 2012. DOI: 10.5301/hip.2012.9075.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.