Contrast-Enhanced Ultrasound (CEUS) Identifies Perfusion Differences Between Tibial Fracture Unions and Non-Unions.
Аннотация
PURPOSE: To assess the value of CEUS in the evaluation of tibial fracture perfusion and its ability to differentiate between physiologic and abnormal fracture healing.
MATERIALS AND
METHODS
From 2014 to 2017, 107 patients with tibial fractures or tibial non-unions underwent CEUS examination. CEUS was performed at the regular follow-up examination 26 weeks after osteosynthesis or before non-union surgery. Time-intensity curves (TICs) of the contrast enhancement in the fracture gap were generated, and volume parameters such as wash-in rate (WiR), peak enhancement (PE) and wash-in perfusion index (WiPI) were quantified.
RESULTS
A total of 34 patients met the inclusion criteria of this study, including 14 consolidated fractures, 12 aseptic non-unions and 8 infected non-unions. WiR, PE and WiPI showed significantly lower values in aseptic non-unions compared to unions (p = 0.009, 0.009, 0.012, resp.). In contrast, infected non-unions showed higher values of WiR, PE and WiPI when compared to unions (p = 0.034, 0.056, 0.029, resp.).
CONCLUSION
CEUS represents a feasible method in the assessment of tibial fracture perfusion. Perfusion differences between aseptic and infected tibial non-unions as well as healing tibial fractures could be detected. The deviation of physiologic fracture perfusion seems to be associated with disturbed osseous regeneration leading to non-union.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.