Application of optimized three-dimensional digital surgical guide plates for complex midfacial fractures.

Xu Guikun, Zhang Xiaojie, Wang Peihan, Long Jie

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

INTRODUCTION

The treatment of midfacial fractures is always difficult. The purpose of this study was to verify whether optimized three-dimensional (3D) digital surgical guide plates combined with preformed titanium plates improved the treatment effect in complex midfacial fractures.

PATIENTS AND

METHODS

Twenty-six patients with complex midfacial fractures were recruited and randomized into three groups: ten for Group A, eight for Group B, and eight for Group C. Group A was treated with a combination of preformed titanium plates and optimized 3D digital surgical guide plates. Group B was treated with preformed titanium plates only. Group C was treated conventionally. Clinical effects, patient-reported outcome measures (PROMs), midfacial contour, facial symmetry, surgical accuracy, △orbital volume (the absolute value of the bilateral orbital volume difference), and maximum deviation were evaluated in each of the three groups.

RESULTS

Group A had the best postoperative clinical effects and patient-reported outcomes. Significant improvements in midfacial contour (L1[0.72±0.29 mm, P = 0.001], L2[1.04±0.46 mm, P < 0.001]), facial symmetry (S1[0.71±0.30 mm, P < 0.001], S2[0.96±0.58 mm, P < 0.001], S3[0.86±0.40 mm, P < 0.001], S5[0.81±0.16 mm, P = 0.003], S8[0.95±0.30 mm, P < 0.001], S9[1.03±0.38 mm, P < 0.001], S11[0.64±0.46 mm, P < 0.001]) and surgical accuracy (M1[R, 0.82±0.31 mm, P < 0.001], M2[R, 0.87±0.44 mm, P < 0.001], M3[L, 0.88±0.22 mm, P = 0.004], M3[R, 1.06±0.31 mm, P = 0.003], M4[L, 0.96±0.45 mm, P = 0.008], M4[R, 1.11±0.57 mm, P = 0.003], M5[R, 0.76±0.26 mm, P < 0.001], M6[L, 1.00±0.46 mm, P = 0.003], M6[R, 1.00±0.58 mm, P = 0.001], M7[0.87±0.53 mm, P = 0.001], M8[R, 0.91±0.53 mm, P < 0.001], M9[R, 0.81±0.32 mm, P = 0.010], M10[R, 1.19±0.42 mm, P = 0.009], M11[L, 0.85±0.51 mm, P = 0.021], M11[R, 0.96±0.49 mm, P = 0.003]) were found in Group A compared with the other two groups. The results of △orbital volume and maximum deviation analysis showed an ideal surgical treatment effect in Group A.

CONCLUSION

Optimized 3D digital guide plates can accurately locate preformed titanium plates and effectively improve the treatment effect in complex midfacial fractures.

Для цитирования: Xu Guikun, Zhang Xiaojie, Wang Peihan, Long Jie. Application of optimized three-dimensional digital surgical guide plates for complex midfacial fractures.. Injury. 2022. DOI: 10.1016/j.injury.2022.03.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.