Special care in dentistry : official publication of the American Association of Hospital Dentists, the Academy of Dentistry for the Handicapped, and the American Society for Geriatric Dentistry · 2021
Customized device for individuals with limited range of motion to insert and remove dentures.
Клинический случайСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Keller Emily L, Alvey Ian A, Valdez Jesus Amadeo
Аннотация
AIM: To develop a device to aid in insertion and removal of dentures in patients with limited range of motion.
CASE REPORT: A 62-year-old male with congenital musculoskeletal system anomaly, severe scoliosis, missing teeth, and poor dentition presented for comprehensive dental care. Patient had significant range of motion limitations resulting in an inability to reach his mouth. A device allowing for independent insertion, removal, and cleaning of dentures was made for patient. Dentures were fabricated and scanned using an intraoral scanner, traditional surgical guide for implant placement was adapted to accommodate neodynium magnets and wooden dowel, and guide was 3D printed. Stainless steel spheres were processed into denture to correspond to magnets in guide. Patient demonstrated ability to independently insert and remove both his maxillary complete denture and mandibular partial denture using device.
CONCLUSION: A successful device for insertion and removal of complete and partial dentures can be fabricated by adapting a surgical guide to incorporate magnets by processing stainless steel spheres into the dentures. This device could be helpful for any individuals demonstrating musculoskeletal system anomalies or range of motion deficits.
CASE REPORT: A 62-year-old male with congenital musculoskeletal system anomaly, severe scoliosis, missing teeth, and poor dentition presented for comprehensive dental care. Patient had significant range of motion limitations resulting in an inability to reach his mouth. A device allowing for independent insertion, removal, and cleaning of dentures was made for patient. Dentures were fabricated and scanned using an intraoral scanner, traditional surgical guide for implant placement was adapted to accommodate neodynium magnets and wooden dowel, and guide was 3D printed. Stainless steel spheres were processed into denture to correspond to magnets in guide. Patient demonstrated ability to independently insert and remove both his maxillary complete denture and mandibular partial denture using device.
CONCLUSION: A successful device for insertion and removal of complete and partial dentures can be fabricated by adapting a surgical guide to incorporate magnets by processing stainless steel spheres into the dentures. This device could be helpful for any individuals demonstrating musculoskeletal system anomalies or range of motion deficits.