Assessment of volume status with bioimpendance prior to hemodialysis and its importance for predicting survival in hemodialysis patients.
Аннотация
BACKGROUND
Optimal fluid management is a physician's everyday challenge in patients on maintenance hemodialysis (HD). Bioimpedance spectroscopy (BIS) is a non-invasive method to estimate body composition, including estimates of fluid overload (FO). Our study aimed to analyze the association between FO and the mortality rate in HD patients.
MATERIALS AND
METHODS
We performed a retrospective single-center cohort study in 92 HD patients. The body composition was measured before HD using the portable whole-body BIS device Body Composition Monitor (BCM). We have analyzed the mortality rates of HD patients in two FO groups, a standard definition FO group (> 1.1 L), and a severe FO group (> 2.5 L) and compared them to mortality rates of patients without FO or without severe FO, respectively.
RESULTS
The mean age of patients was 64.3 ± 13.0 years, mean dialysis vintage 64 months, 60.9% were men. 68 (73.9%) patients had FO of > 1.1 L and 30 (32.6%) had FO of > 2.5 L. During the follow-up period of 1,020 ± 417 days, 29 (31.5%) patients died. Kaplan-Meier survival analysis showed that patients with FO > 2.5 L had worse survival (p = 0.039). In a Cox regression model, which included FO > 2.5 L, age, dialysis vintage, hemoglobin, C-reactive protein, and albumin, only FO > 2.5 L and advanced age turned out to be predictors of death (p = 0.044 and p = 0.001, respectively).
CONCLUSION
HD patients with FO > 2.5 L before HD have poorer survival than patients with normohydration or lower overhydration.