Biomechanical Comparison of Use of Two Screws versus Three Screws Per Fragment with Locking Plate Constructs under Cyclic Loading in Compression in a Fracture Gap Model.
Аннотация
OBJECTIVES
The aim of this study was to measure and compare the stiffness and cyclic fatigue of two plate-bone model constructs, with either two or three locking screws per fragment, under cyclic compression.
METHODS
A 10-hole 3.5 mm stainless steel locking compression plate (LCP) was fixed 1 mm from a synthetic bone model in which the fracture gap was 47 mm. Two groups of 10 constructs, prepared with either two or three bicortical locking screws placed at the extremities of each fragment, were tested in a load-controlled compression test until failure.
RESULTS
The three-screw constructs were stiffer than the two-screw constructs (196.75 ± 50.48 N/mm and 102.43 ± 22.93 N/mm, respectively) and the actuator displacements of the two-screw constructs were higher (18.02 ± 1.07 mm) than those of the three-screw constructs (14.48 ± 2.25 mm). The number of cycles to failure of the two-screw constructs was significantly lower (38,337.50 ± 2,196.98) than the that of the three-screw constructs (44,224.00 ± 1,515.24). Load at irreversible deformation was significantly lower in the two-screw constructs (140.93 ± 13.39 N) than in the three-screw constructs (184.27 ± 13.17 N). All constructs failed by plate bending at the gap between the two cylinders.
CLINICAL SIGNIFICANCE: Omission of the third innermost locking screw during bridging osteosynthesis subjected to compression forces led to a 13.3% reduction in the number of cycles to failure and a 23.5% reduction of the load withstood by the plate before plastic deformation occurred.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.