MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/01477447-20130327-34

Медицинская библиотека · Orthopedics · 2013

Severe persistent synovitis after cobalt-chromium total knee arthroplasty requiring revision.

Thakur Raman R, Ast Michael P, McGraw Michael, Bostrom Mathias P, Rodriguez Jose A, Parks Michael L

Клинический случайСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Implant-related hypersensitivity is a well-established cause of failure after total hip arthroplasty but is a rare complication after total knee arthroplasty (TKA). It remains a relatively unpredictable and poorly understood cause of implant-related failure. This article describes 5 patients (6 knees) who presented with persistent pain and hypertrophic synovitis after TKA using a cobalt-chromium component. Extensive perioperative workup, including white blood cell count, erythrocyte sedimentation rate, C-reactive protein, joint aspiration, and intraoperative cultures, ruled out infection as a cause of the symptoms. All knees demonstrated appropriate ligamentous balance and were well aligned, with all components noted to be well fixed at revision. In all patients, the clinical condition improved dramatically after revision to zirconium femoral and titanium metal-backed tibial components. Pain and functional outcome scores improved in all patients. Intraoperative histopathology revealed a thickened synovium with either a predominantly lymphocytic or histiocytic monocellular response. Final pathology confirmed that no infection was present in any patient. The goal of TKA is to produce a well-performing, pain-free joint. When patients present with recurrent pain and synovitis after TKA, infection must be excluded. When infection and instability have been excluded, metal hypersensitivity should be considered as a cause of primary TKA failure. In these patients, revision to a zirconium femoral component can provide predictable and effective clinical improvement.

Для цитирования: Thakur Raman R, Ast Michael P, McGraw Michael, Bostrom Mathias P, Rodriguez Jose A, Parks Michael L. Severe persistent synovitis after cobalt-chromium total knee arthroplasty requiring revision.. Orthopedics. 2013. DOI: 10.3928/01477447-20130327-34.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.