Functional outcomes of the failed plate fixation in distal tibial fractures salvaged by hexapod external fixator.

Molepo Maketo, Barnard Annette-Christi, Birkholtz Franz, Tetsworth Kevin, Glatt Vaida, Hohmann Erik

СтатьяПеревод в очереди

Аннотация

PURPOSE: The purpose of this study was to evaluate the clinical and functional outcomes of failed plate fixation in distal tibia fractures salvaged with hexapod circular fixators.

MATERIALS AND

METHODS

The database of a specialized limb reconstruction center was searched for all patients with failed plate fixation undergoing limb reconstruction with a circular external fixator between 2008 and 2017. Patients between the ages of 18-65 years, with a symptomatic distal tibia malunion or non-union following plate and screw fixation were included. The SF-12 and Foot Function Index (FFI) scoring systems were used to measure clinical and functional outcomes.

RESULTS

Ten patients with a mean age of 38 ± 13 years met the inclusion criteria. Seven patients had an infected non-union, two hypertrophic non-unions, and one a malunion. The mean follow-up was 41.7 ± 28.3 months. The mean duration of external fixation was 232.9 ± 146.6 days. The SF-12 demonstrated a mean score of 49.4 ± 7.7 for the physical component and a mean score of 55.3 ± 8.1 for the mental component. Five patients (50%) scored above 45 points for the SF12 physical component, and nine patients (90%) scored above 45 points for the mental component, indicating good outcome can be achieved. The mean FFI score was 24.9 ± 19.9, and six patients had a score below 14 points (good outcome). Radiological union was observed in all 10 patients at a mean of 29 ± 14 months.

CONCLUSIONS

The results of this study suggest that hexapod circular external fixation is an attractive surgical alternative for the treatment of failed plate fixation of distal tibial fractures, and can reliably achieve bony union and result in very satisfactory clinical outcomes.

LEVEL OF EVIDENCE: Level IV case series.

Для цитирования: Molepo Maketo, Barnard Annette-Christi, Birkholtz Franz, Tetsworth Kevin, Glatt Vaida, Hohmann Erik. Functional outcomes of the failed plate fixation in distal tibial fractures salvaged by hexapod external fixator.. European journal of orthopaedic surgery & traumatology : orthopedie traumatologie. 2018. DOI: 10.1007/s00590-018-2231-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.