Impact of Femoral Neck Cortical Bone Defect Induced by Core Decompression on Postoperative Stability: A Finite Element Analysis.

Yuan Daizhu, Wu Zhanyu, Luo Siwei, Zou Qiang, Zou Zihao, Ye Chuan

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To analyze the impact of femoral neck cortical bone defect induced by core decompression on postoperative biomechanical stability using the finite element method.

METHODS

Five finite element models (FEMs) were established, including the standard operating model and four models of cortical bone defects at different portions of the femoral neck (anterior, posterior, superior, and inferior). The maximum stress of the proximal femur was evaluated during normal walking and walking downstairs.

RESULTS

Under both weight-bearing conditions, the maximum stress values of the five models were as follows: femoral neck (inferior) > femoral neck (superior) > femoral neck (posterior) > femoral neck (anterior) > standard operation. Stress concentration occurred in the areas of femoral neck cortical bone defect. Under normal walking, the maximum stress of four bone defect models and its increased percentage comparing the standard operation were as follows: anterior (17.17%), posterior (39.02%), superior (57.48%), and inferior (76.42%). The maximum stress was less than the cortical bone yield strength under normal walking conditions. Under walking downstairs, the maximum stress of four bone defect models and its increased percentage comparing the standard operation under normal walking were as follows: anterior (36.75%), posterior (67.82%), superior (83.31%), and inferior (103.65%). Under walking downstairs conditions, the maximum stress of bone defect models (anterior, posterior, and superior) was less than the yield strength of cortical bone, while the maximum stress of bone defect model (inferior) excessed yield strength value.

CONCLUSIONS

The femoral neck cortical bone defect induced by core decompression can carry out normal walking after surgery. To avoid an increased risk of fracture after surgery, walking downstairs should be avoided when the cortical bone defect is inferior to the femoral neck except for the other three positions (anterior, posterior, and superior).

Для цитирования: Yuan Daizhu, Wu Zhanyu, Luo Siwei, Zou Qiang, Zou Zihao, Ye Chuan. Impact of Femoral Neck Cortical Bone Defect Induced by Core Decompression on Postoperative Stability: A Finite Element Analysis.. BioMed research international. 2022. DOI: 10.1155/2022/3667891.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.