MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5152/j.aott.2022.21157

Медицинская библиотека · Acta orthopaedica et traumatologica turcica · 2022

Dorsal plating versus volar plating with limited dorsal open reduction in the management of AO type C3 distal radius fractures with impacted articular fragments: A retrospective comparative study.

Lee Jae Hoon, Ahn Jung Tae, Baek Jong Hun

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

The aim of this study was to compare the outcomes of dorsal plating versus volar plating with limited dorsal open reduction in the management of AO type C3 distal radius fractures with impacted articular fragments.

METHODS

Thirty patients who underwent dorsal plating (Group A) (14 females, 16 males; mean age = 56.8 ± 10.1 years) and 28 who underwent volar plating with limited dorsal open reduction (Group B) (12 females, 16 males; mean age = 55.6 ± 17.7 years) for type C3 distal radius fractures with impacted articular fragments between 2006 and 2019 were retrospectively analyzed. The mean follow-up was 14.5 ± 3.2 months in group A and 13.2 ± 2.4 months in group B. The articular step-off, articular gap and joint penetration by screws on the computed tomography scans were used for radiologic evaluation. The functional outcomes were evaluated with range of motion, grip power, Quick Disabilities of the Arm, Shoulder, and Hand (DASH) score, and Mayo wrist score.

RESULTS

No significant difference was found in the step-off distance at 1 year after surgery between the two groups (P < 0.05). The ranges of extension, rotation, and radial and ulnar deviations did not differ between the groups. However, group B had a significantly higher range of flexion in the wrist joint than Group A (P = 0.010). The grip power, DASH score, and Mayo wrist score did not also differ between the groups. Implant removal owing to any discomfort at the operative site was performed in 15 patients (63%) in Group A and 7 patients (28%) in Group B.

CONCLUSION

Similar clinical results can be obtained by both dorsal plating and volar plating with limited dorsal open reduction in treating type C3 distal radius fractures with impacted articular fragments. However, volar plating with limited dorsal open reduction can provide better wrist flexion with a low incidence of complications associated with implantation.

LEVEL OF EVIDENCE: Level III, Therapeutic Study.

Для цитирования: Lee Jae Hoon, Ahn Jung Tae, Baek Jong Hun. Dorsal plating versus volar plating with limited dorsal open reduction in the management of AO type C3 distal radius fractures with impacted articular fragments: A retrospective comparative study.. Acta orthopaedica et traumatologica turcica. 2022. DOI: 10.5152/j.aott.2022.21157.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.