Automatic exposure compensation of digital radiographic technologies does not affect alveolar bone-level measurement.

Gaêta-Araujo Hugo, Oliveira-Santos Nicolly, de Oliveira Reis Larissa, Nascimento Eduarda Helena Leandro, Oliveira-Santos Christiano

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To evaluate whether the automatic exposure compensation in the presence of high-density materials can affect the measurement of alveolar bone level.

METHODS

Thirty regions of seven dry skulls and six mandibles were radiographed with and without a high-density material, using two digital radiographic technologies: photostimulable phosphor plate (PSP, Digora Optime) and sensor (CMOS, Digora Toto), totaling 120 images. The distances from the cement-enamel junction to the alveolar bone crest were measured using cone-beam computed tomography (CBCT) images to represent the reference standard. The same measurements of alveolar bone level and the average of the pixel values of the image were evaluated on the radiographs. Paired t test compared the average pixel values and alveolar bone-level measurements between images with and without high-density material. One-way analysis of variance compared the difference between radiographic and CBCT measurements (α = 0.05).

RESULTS

The high-density material reduced the pixel values in PSP (p = 0.002) and CMOS (p < 0.001) technologies, demonstrating the AEC functioning in both technologies. There was no difference in bone-level measurements between the images without and with the high-density material for both technologies (p ≥ 0.091), or between the tomographic and radiographic measurements (p ≥ 0.319).

CONCLUSION

In the presence of high-density material, the automatic exposure compensation reduces the average pixel values of the images (i.e., images get darker), but does not influence the radiographic measurements of alveolar bone level.

Для цитирования: Gaêta-Araujo Hugo, Oliveira-Santos Nicolly, de Oliveira Reis Larissa, Nascimento Eduarda Helena Leandro, Oliveira-Santos Christiano. Automatic exposure compensation of digital radiographic technologies does not affect alveolar bone-level measurement.. Oral radiology. 2022. DOI: 10.1007/s11282-022-00599-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.