Femoral fixation strength following soft-tissue posterolateral corner reconstruction using fibular-based technique: Biomechanical analysis of four techniques in normal and low-density synthetic bone.

Gallo Robert A, Sathyendra Vikram, Sharkey Neil A, Lewis Gregory S

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Optimal femoral fixation of soft-tissue grafts has been described for anterior cruciate ligament reconstruction. Posterolateral corner reconstruction differs from ACL reconstruction in two ways: (a) soft-tissue fixation into the femur requires two tails and (b) the line of force is different. Our purpose was to determine the optimal femoral fixation of soft-tissue grafts during posterolateral corner reconstructions. We hypothesized that interference screw fixation is the strongest technique in normal-density lateral femoral condyle, whereas, cortically-based fixation techniques are stronger methods in low-density lateral femoral condyle.

METHODS

We evaluated elongation during cyclic loading, yield load, peak load-to-failure, and stiffness of four soft-tissue graft femoral fixation methods during posterolateral corner reconstruction. Our model included bovine flexor tendons and contoured synthetic bones. Grafts were secured to the lateral epicondyle in normal- or low-density bone models using spiked washer, button, interference screw, or button and interference screw. Five specimens for each were tested in each bone density. Analysis of variance using Tukey-Kramer adjustment for multiple hypothesis testing was used. Six cadaver bones whose density was analyzed using computerized tomography scan quantitation were tested using interference screw fixation.

RESULTS

No method produced significantly stronger yield load or peak load-to-failure in normal-density bone. In low-density bone, cortically-based methods produced significantly higher yield load or peak load-to-failure. Yield load or peak load-to-failure was significantly higher in normal-density bone when using spiked washer or interference screw fixation.

CONCLUSION

No femoral fixation method tested produced superior yield load or peak load-to-failure. Spiked washer and interference screw fixation are inferior fixation methods in low-density bone.

CLINICAL RELEVANCE: For fibular-based posterolateral corner reconstructions, all fixation methods tested are acceptable in high-density bone, while cortical fixation methods should be considered in low-density bone.

Для цитирования: Gallo Robert A, Sathyendra Vikram, Sharkey Neil A, Lewis Gregory S. Femoral fixation strength following soft-tissue posterolateral corner reconstruction using fibular-based technique: Biomechanical analysis of four techniques in normal and low-density synthetic bone.. The Knee. 2015. DOI: 10.1016/j.knee.2015.06.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.