INTRODUCTION

Whether to conserve or remove titanium miniplates after rigid internal fixation of mandibular fractures still remains controversial. Miniplates could affect the biomechanical behaviour of the mandible in case of trauma, and therefore cause more complex fractures.

MATERIALS AND

METHODS

An experimental study, consisting in simulating a mandibular trauma, was designed in order to compare the fractures caused by an impact on the mandible in the presence or absence of an internal fixation. We simulated an impact on the right parasymphysis region in 10 post-mortem human subjects, according to the Charpy impact test method at an impact speed of 7.4 m/s, using a 5 kg test impactor.

RESULTS

In the control group, the fracture lines were vertical and straight, without comminution. In the miniplate group, the fractures occurred close to the miniplates (4 cases) and under the miniplates (one case). The fracture lines were more complex, even comminuted in 2 cases. Thus, miniplates impacted the biomechanical behavior of the mandible, resulting in more complex fractures.

CONCLUSION

Our experimental study highlighted the impact of the presence of miniplates on the mandible in case of trauma, and the risk of causing more complex fractures. We therefore recommend further investigations to determine if titanium miniplates should be systematically removed after bone healing, in patients with a higher risk of trauma in relation with previous assault injuries, alcohol or substance abuse, the practice of fighting or contact sport/activities, and soldiers.

Для цитирования: Graillon Nicolas, Guyot Laurent, Thollon Lionel, Godio-Raboutet Yves, Roux Marc-Kevin Le, Foletti Jean-Marc. Do mandibular titanium miniplates affect the biomechanical behaviour of the mandible? A preliminary experimental study.. Journal of stomatology, oral and maxillofacial surgery. 2022. DOI: 10.1016/j.jormas.2022.02.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.