Antiplatelet effects of hydroxychloroquine in patients with systemic lupus erythematosus evaluated by the total thrombus-formation analysis system (T-TAS).
Аннотация
OBJECTIVES
Hydroxychloroquine (HCQ) has been shown to reduce thrombotic events in patients with SLE. However, the antiplatelet effects of HCQ are only supported by the platelet aggregation assay, which is a non-physiological test. The total thrombus-formation analysis system (T-TAS) is a microchip-based flow chamber system that mimics physiological conditions and allows for the quantitative analysis of thrombogenicity. The present study investigated the antiplatelet effects of HCQ using T-TAS.
METHODS
This was a single-centre cross-sectional study on 57 patients with SLE. We measured the area under the pressure curve for 10 min (PL-AUC10) and the time to 10 kPa (T10) in patients with SLE using T-TAS and examined their relationships with the use of HCQ. PL-AUC10 and platelet aggregation were also measured at several HCQ concentrations using blood samples from healthy donors.
RESULTS
PL-AUC10 was significantly lower in the HCQ/real body weight (RBW) ≥5 mg/kg group than in the <5 mg/kg group, while T10 was similar, indicating that HCQ inhibited overall thrombus formation rather than the initiation of thrombus formation. The antiplatelet effects of HCQ were initially detected at HCQ/RBW of approximately 4 mg/kg and reached a plateau at around 5.5 mg/kg. The administration of HCQ/RBW >4.6 mg/kg clearly exerted antiplatelet effects. Additionally, HCQ inhibited thrombus formation in T-TAS and the platelet aggregation response to epinephrine in a dose-dependent manner.
CONCLUSIONS
We demonstrated the antiplatelet effects of HCQ under conditions simulating the physiological environment by using T-TAS and identified the range of doses at which HCQ exerted antiplatelet effects.