MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3904/kjim.2016.397

Медицинская библиотека · The Korean journal of internal medicine · 2018

Standardized, musculoskeletal ultrasonographic reference values for healthy Korean adults.

Kim Hyun-Sook, Kim Hae-Rim, Kim Bo Young, Kim Yun Sung, Jung Young Ok, Choi Sung Jae, Kim Hyun-Ok, Hwang Jiwon, Lee Sunggun, Kim Hyoun-Ah, Bang So Young, Chai Ji-Young, Park Sung-Hoon, Yoon Chong-Hyeon

СтатьяПеревод в очереди

Аннотация

BACKGROUND/AIMS: To define standard reference values for musculoskeletal ultrasonography (MSUS) in Korea.

METHODS

A total of 251 healthy adults were recruited for this study. Ultrasonography was performed by experienced rheumatologists who had undergone four appropriate training programs in Korea. A General Electric LOGIQ electronic ultrasound device fitted with a 12 MHz linear transducer was employed. Mean values ± standard deviations (SDs) were defined as standard reference values. Intraclass correlation coefficients was employed to evaluate the extent of inter- and intraobserver agreement when MSUS measurements were made.

RESULTS

The 251 study participants included 122 males. Mean subject age was 28.6 years. The average bone-to-capsule distance of the right-side second and third metacarpophalangeal (MCP) joints were 0.68 and 0.72 mm respectively, and those of the left-side joints 0.62 and 0.68 mm. The cartilage thicknesses of the rightside second and third MCP joints were 0.55 and 0.55 mm, and those of the leftside joints were 0.55 and 0.56 mm, respectively. The bone-to-capsule distances of the right and left wrists were 0.80 and 0.82 mm. In 12.4% of participants (31/251), the erosion score of the humeral head was 1.71. In the right-side knee joint, mean cartilage thicknesses of the medial and lateral condyles were 1.86 and 2.03 mm in longitudinal scans. High overall interobserver agreement was evident after appropriate training that included instruction on standard MSUS methodology.

CONCLUSION

We defined standard reference values for MSUS in healthy Korean adults. The reliabilities of interobserver agreements were high after appropriate training program.

Для цитирования: Kim Hyun-Sook, Kim Hae-Rim, Kim Bo Young, Kim Yun Sung, Jung Young Ok, Choi Sung Jae, Kim Hyun-Ok, Hwang Jiwon, Lee Sunggun, Kim Hyoun-Ah, Bang So Young, Chai Ji-Young, Park Sung-Hoon, Yoon Chong-Hyeon. Standardized, musculoskeletal ultrasonographic reference values for healthy Korean adults.. The Korean journal of internal medicine. 2018. DOI: 10.3904/kjim.2016.397.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.