Clinical orthopaedics and related research · 2012
Second-generation modular acetabular components provide fixation at 10 to 16 years.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Lachiewicz Paul F, Soileau Elizabeth S
Аннотация
BACKGROUND: First-generation modular titanium fiber-metal-coated acetabular components had high rates of wear, pelvic osteolysis, and liner dissociation. Second-generation components were designed to reduce the incidence of these problems but it is unclear whether the changes achieved these goals.
QUESTIONS/PURPOSES: We asked the following questions: (1) Is the risk of revision surgery for loosening, wear, or liner dissociation low with the second-generation acetabular component? (2) Is the rate of pelvic osteolysis low? (3) Can the liner be exchanged without bone cement?
METHODS: We retrospectively reviewed prospectively collected data from 99 patients (118 hips) undergoing THAs with one second-generation modular titanium acetabular component with routine screw fixation and conventional polyethylene. The minimum followup was 10 years (mean, 12 years; range, 10-16 years). We obtained Harris hip scores and examined radiographs for loosening and osteolysis.
RESULTS: At last followup, all acetabular components were well fixed and no titanium shell had been revised or removed. No liner had dissociation. At most recent followup, the mean Harris hip score was 89. We observed pelvic osteolysis in eight hips (7%). There were three reoperations for dislocation (head-liner exchange only) and three loose femoral components revised. Two liners (at 11 and 14 years) were exchanged for wear-pelvic osteolysis.
CONCLUSIONS: This second-generation modular titanium fiber-metal-coated acetabular component with screw fixation had no loosening, no liner dissociation, and a low rate of pelvic osteolysis at 10 to 16 years. Liner exchange is practical without use of cement. We continue to use this component with highly crosslinked polyethylene liners.
LEVEL OF EVIDENCE: Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
QUESTIONS/PURPOSES: We asked the following questions: (1) Is the risk of revision surgery for loosening, wear, or liner dissociation low with the second-generation acetabular component? (2) Is the rate of pelvic osteolysis low? (3) Can the liner be exchanged without bone cement?
METHODS: We retrospectively reviewed prospectively collected data from 99 patients (118 hips) undergoing THAs with one second-generation modular titanium acetabular component with routine screw fixation and conventional polyethylene. The minimum followup was 10 years (mean, 12 years; range, 10-16 years). We obtained Harris hip scores and examined radiographs for loosening and osteolysis.
RESULTS: At last followup, all acetabular components were well fixed and no titanium shell had been revised or removed. No liner had dissociation. At most recent followup, the mean Harris hip score was 89. We observed pelvic osteolysis in eight hips (7%). There were three reoperations for dislocation (head-liner exchange only) and three loose femoral components revised. Two liners (at 11 and 14 years) were exchanged for wear-pelvic osteolysis.
CONCLUSIONS: This second-generation modular titanium fiber-metal-coated acetabular component with screw fixation had no loosening, no liner dissociation, and a low rate of pelvic osteolysis at 10 to 16 years. Liner exchange is practical without use of cement. We continue to use this component with highly crosslinked polyethylene liners.
LEVEL OF EVIDENCE: Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
Предметные рубрики MeSH
AcetabulumAdultAgedAged, 80 and overArthroplasty, Replacement, HipBone CementsBone ScrewsFemaleHip JointHip ProsthesisHumansKaplan-Meier EstimateMaleMiddle AgedNorth CarolinaOsteolysisPolyethyleneProsthesis DesignProsthesis FailureRadiographyRange of Motion, ArticularRecovery of FunctionReoperationRetrospective StudiesRisk AssessmentRisk FactorsTime FactorsTitaniumTreatment OutcomeYoung Adult