Super-resolution musculoskeletal MRI using deep learning.
Аннотация
PURPOSE: To develop a super-resolution technique using convolutional neural networks for generating thin-slice knee MR images from thicker input slices, and compare this method with alternative through-plane interpolation methods.
METHODS
We implemented a 3D convolutional neural network entitled DeepResolve to learn residual-based transformations between high-resolution thin-slice images and lower-resolution thick-slice images at the same center locations. DeepResolve was trained using 124 double echo in steady-state (DESS) data sets with 0.7-mm slice thickness and tested on 17 patients. Ground-truth images were compared with DeepResolve, clinically used tricubic interpolation, and Fourier interpolation methods, along with state-of-the-art single-image sparse-coding super-resolution. Comparisons were performed using structural similarity, peak SNR, and RMS error image quality metrics for a multitude of thin-slice downsampling factors. Two musculoskeletal radiologists ranked the 3 data sets and reviewed the diagnostic quality of the DeepResolve, tricubic interpolation, and ground-truth images for sharpness, contrast, artifacts, SNR, and overall diagnostic quality. Mann-Whitney U tests evaluated differences among the quantitative image metrics, reader scores, and rankings. Cohen's Kappa (κ) evaluated interreader reliability.
RESULTS
DeepResolve had significantly better structural similarity, peak SNR, and RMS error than tricubic interpolation, Fourier interpolation, and sparse-coding super-resolution for all downsampling factors (p < .05, except 4 × and 8 × sparse-coding super-resolution downsampling factors). In the reader study, DeepResolve significantly outperformed (p < .01) tricubic interpolation in all image quality categories and overall image ranking. Both readers had substantial scoring agreement (κ = 0.73).
CONCLUSION
DeepResolve was capable of resolving high-resolution thin-slice knee MRI from lower-resolution thicker slices, achieving superior quantitative and qualitative diagnostic performance to both conventionally used and state-of-the-art methods.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.