DOI 10.1097/bot.0000000000001110
Nail Fit: Does Nail Diameter to Canal Ratio Predict the Need for Exchange Nailing in the Setting of Aseptic, Hypertrophic Femoral Nonunions?
Аннотация
OBJECTIVES
To evaluate patient-independent risk factors for aseptic femoral hypertrophic nonunion requiring exchange nailing, with particular reference to the fit of the nail at the isthmus within the canal.
DESIGN
Retrospective case control study.
SETTING
Level 1 trauma center.
MAIN OUTCOME MEASUREMENTS: Between 2008 and 2012, 211 patients without any patient-dependent risk factors for nonunion were treated with a locked reamed intramedullary nail for a femoral shaft fracture. Twenty-three cases went on to hypertrophic nonunion requiring exchange nailing (treatment group) and 188 cases went on to union (control group). Patient-independent risk factors for exchange nailing were documented.
RESULTS
Patient-independent risk factors for exchange nailing were poor fracture reduction [Odds ratio (OR): 11.5, 95% confidence interval (CI), 4.0-33.4, P < 0.001], open fracture (OR: 7.6, 95% CI, 3.0-19.6, P = 0.004), Winquist classification of 4 (OR: 4.4, 95% CI, 1.9-6.7, P = 0.016), and poor nail fit (OR: 10.3, 95% CI, 5.1-28.4, P < 0.001). Multivariate analysis revealed nail fit as an independent predictor of femoral nonunion requiring exchange nailing (OR: 11.4, 95% CI, 6.9-15.2, P < 0.001). Moreover, we found a direct relationship between increasingly poor nail fit and increased risk of exchange nailing, with the criterion occurring at a nail fit ratio <70%.
CONCLUSION
When proceeding to femoral fracture reamed intramedullary nailing, we recommend a minimum nail fit of 70% at the isthmus and ideally 90% or more, to avoid surgical reintervention.
LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.