Nail Fit: Does Nail Diameter to Canal Ratio Predict the Need for Exchange Nailing in the Setting of Aseptic, Hypertrophic Femoral Nonunions?

Millar Michael J, Wilkinson Andrew, Navarre Pierre, Steiner Joel, Vohora Ashray, Hardidge Andrew, Edwards Elton

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To evaluate patient-independent risk factors for aseptic femoral hypertrophic nonunion requiring exchange nailing, with particular reference to the fit of the nail at the isthmus within the canal.

DESIGN

Retrospective case control study.

SETTING

Level 1 trauma center.

MAIN OUTCOME MEASUREMENTS: Between 2008 and 2012, 211 patients without any patient-dependent risk factors for nonunion were treated with a locked reamed intramedullary nail for a femoral shaft fracture. Twenty-three cases went on to hypertrophic nonunion requiring exchange nailing (treatment group) and 188 cases went on to union (control group). Patient-independent risk factors for exchange nailing were documented.

RESULTS

Patient-independent risk factors for exchange nailing were poor fracture reduction [Odds ratio (OR): 11.5, 95% confidence interval (CI), 4.0-33.4, P < 0.001], open fracture (OR: 7.6, 95% CI, 3.0-19.6, P = 0.004), Winquist classification of 4 (OR: 4.4, 95% CI, 1.9-6.7, P = 0.016), and poor nail fit (OR: 10.3, 95% CI, 5.1-28.4, P < 0.001). Multivariate analysis revealed nail fit as an independent predictor of femoral nonunion requiring exchange nailing (OR: 11.4, 95% CI, 6.9-15.2, P < 0.001). Moreover, we found a direct relationship between increasingly poor nail fit and increased risk of exchange nailing, with the criterion occurring at a nail fit ratio <70%.

CONCLUSION

When proceeding to femoral fracture reamed intramedullary nailing, we recommend a minimum nail fit of 70% at the isthmus and ideally 90% or more, to avoid surgical reintervention.

LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.

Для цитирования: Millar Michael J, Wilkinson Andrew, Navarre Pierre, Steiner Joel, Vohora Ashray, Hardidge Andrew, Edwards Elton. Nail Fit: Does Nail Diameter to Canal Ratio Predict the Need for Exchange Nailing in the Setting of Aseptic, Hypertrophic Femoral Nonunions?. Journal of orthopaedic trauma. 2018. DOI: 10.1097/bot.0000000000001110.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.