Functional Results of Unstable (Type 2) Distal Clavicle Fractures Treated with Superior Anterior Locking Plate.
Аннотация
BACKGROUND
The treatment of distal clavicle fracture is always a challenge, as it is mostly unstable and has higher rate of delayed union, malunion, non-union and associated acromioclavicular arthritis. So the management of these fractures remains controversial. The purpose of this study is to evaluate the functional results of Type 2 distal end clavicle fractures treated with superior anterior locking plate.
METHODS
From June 2011 to August 2015 a retrospective study of12 male patients (mean age of 41.3 years) 11 with unilateral and 1 with bilateral distal clavicle fractures treated with superior anterior locking plate was done. They were evaluated at regular intervals with mean follow up of 14 months(12-18 months). Those with minimum one year follow up were included in our study. All were evaluated for the functioning of the shoulder joint by both Oxford shoulder score and Quick DASH scores, rate of bone union, complications and earliest time for return to work.
RESULTS
All fractures union seen within 6-8 weeks (mean time: 7.1 weeks). All had good shoulder range of motion. The average oxford shoulder and Quick DASH score were 46.2 and 6.5. There were no major complications in our study viz. non-union, plate failure, secondary fracture. But one patient had superficial wound infection. All patients returned to work within 3 months of postoperative period.
CONCLUSION
Displaced distal clavicle fractures treated with superior anterior locking plates achieved excellent results in terms of bony union with rarely any complications and demonstrate promising results with this novel technique.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.