m+Medelevator.RU
← Поиск публикаций
Journal of the mechanical behavior of biomedical materials · 2022

Fracture load of different veneered and implant-supported 4-UNIT cantilever PEEK fixed dental prostheses.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Micovic Soldatovic Danka, Liebermann Anja, Huth Karin C, Stawarczyk Bogna

Аннотация

OBJECTIVES: To determine the fracture load before and after artificial aging of implant-supported 4-unit cantilever fixed dental prostheses (FDP) with frameworks made of two differently filled polyetheretherketone (PEEK) compounds and veneered using three different techniques.

METHODS: A total of 120 duplicate 4-unit FDP frameworks were produced (n = 60 milled from PEEK, 20% TiO2 filled and n = 60 pressed from PEEK, 30% TiO2 filled) and veneered using three different techniques: (i) digital veneerings, (ii) conventional resin composite veneerings and (iii) prefabricated veneers (n = 20 per subgroup). The FDPs were adhesively bonded to titanium abutments and the fracture load was measured in a universal testing machine (1 mm/min) before and after artificial aging in a mastication simulator (1,200,000 cycles, 50 N, TC: 5/55 °C, 6000 cycles). The fracture patterns were analyzed using digital microscopy. Data were analyzed using the Kolmogorov-Smirnov test, two-way ANOVA, post hoc Scheffé, Chi2-test (p < 0.05), and Weibull modulus m, as well as fracture patterns using the Ciba-Geigy table.

RESULTS: Veneering technique and filler content significantly affected the fracture load (p < 0.001). Prefabricated veneers showed higher fracture load (p ≤ 0.001) whereas digital and conventional veneerings were similar (p = 0.451). PEEK with 30% filler content presented higher fracture load (p < 0.001) compared with PEEK with 20%. Aging showed no effect on fracture load (p = 0.176). Regarding fracture types, no significant differences were found among the groups (p = 0.055).

CONCLUSIONS: Filler content of PEEK compound as well as veneering technique influenced fracture load while aging had no effect on fracture load. FDPs made of PEEK with 30% of filler content veneered using prefabricated veneers had the highest fracture resistance.