MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00590-021-03160-4

Медицинская библиотека · European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2022

The comparison of stress and strain between custom-designed bone plates (CDBP) and locking compression plate (LCP) for distal femur fracture.

Shams Seyedeh Fatemeh, Mehdizadeh Alireza, Movahedi Mohammad Mehdi, Paydar Shahram, Haghpanah Seyyed Arash

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Distal femur fracture is considered one of the most common fractures due to high-energy traumas such as car accidents or low-energy traumas such as osteoporosis. Locking plates are orthopedic implants used for stabilized femur fracture. Thus, designing a bone plate fitted exactly with the patient's bone and correctly fixing bone segments are required for better fracture healing.

OBJECTIVES

This study aims to design a bone plate based on anthropometric characteristics of patients' femurs and compare performing custom-designed bone plates (CDBP) with the locking compression plate (LCP) by finite element method.

MATERIALS AND

METHODS

In this analytical study, a 3D model of four patients' femur and CDBP were firstly designed in MIMICS 19.0 based on the patient's femur anatomy. After designing the bone plate, the CDBPs and LCP were fixed on the bone and analyzed by finite element method (FEM) in ANSYS, and stress and strain of bone plates were also compared.

RESULTS

The maximum principal stress for all 3D models of patients' fracture femur by CDBPs was stabilized better than LCP with a decrease by 39.79, 12.54, 9.49, and 20.29% in 4 models, respectively. Also, in all models, the strain of CDBPs is less than LCP. Among the different thicknesses considered, the bone plate with 5 mm thickness showed better stress and strain distribution than other thicknesses.

CONCLUSION

Customized bone plate designed based on patient's femur anatomical morphology shows better bone-matching plate, resulting in increasing the quality of the fracture healing and fails to any need for additional shaping.

TRIAL REGISTRATION NUMBER: Design and analysis of an implant were investigated in this study. There was no intervention in the diagnosis and treatment of patients and the study was not a clinical trial.

Для цитирования: Shams Seyedeh Fatemeh, Mehdizadeh Alireza, Movahedi Mohammad Mehdi, Paydar Shahram, Haghpanah Seyyed Arash. The comparison of stress and strain between custom-designed bone plates (CDBP) and locking compression plate (LCP) for distal femur fracture.. European journal of orthopaedic surgery & traumatology : orthopedie traumatologie. 2022. DOI: 10.1007/s00590-021-03160-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.