Reliability of 3-Dimensional Measures of Single-Leg Drop Landing Across 3 Institutions: Implications for Multicenter Research for Secondary ACL-Injury Prevention.

Myer Gregory D, Bates Nathaniel A, DiCesare Christopher A, Barber Foss Kim D, Thomas Staci M, Wordeman Samuel C, Sugimoto Dai, Roewer Benjamin D, Medina McKeon Jennifer M, Di Stasi Stephanie L, Noehren Brian W, McNally Michael, Ford Kevin R, Kiefer Adam W, Hewett Timothy E

СтатьяМногоцентровое исследованиеПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

CONTEXT: Due to the limitations of single-center studies in achieving appropriate sampling with relatively rare disorders, multicenter collaborations have been proposed to achieve desired sampling levels. However, documented reliability of biomechanical data is necessary for multicenter injury-prevention studies and is currently unavailable.

OBJECTIVE

To measure the reliability of 3-dimensional (3D) biomechanical waveforms from kinetic and kinematic variables during a single-leg landing (SLL) performed at 3 separate testing facilities.

DESIGN

Multicenter reliability study.

SETTING

3 laboratories.

PATIENTS: 25 female junior varsity and varsity high school volleyball players who visited each facility over a 1-mo period.

INTERVENTION: Subjects were instrumented with 43 reflective markers to record 3D motion as they performed SLLs. During the SLL the athlete balanced on 1 leg, dropped down off of a 31-cm-high box, and landed on the same leg. Kinematic and kinetic data from both legs were processed from 2 trials across the 3 laboratories.

MAIN OUTCOME MEASURES: Coefficients of multiple correlations (CMC) were used to statistically compare each joint angle and moment waveform for the first 500 ms of landing.

RESULTS

Average CMC for lower-extremity sagittal-plane motion was excellent between laboratories (hip .98, knee .95, ankle .99). Average CMC for lower-extremity frontal-plane motion was also excellent between laboratories (hip .98, knee .80, ankle .93). Kinetic waveforms were repeatable in each plane of rotation (3-center mean CMC ≥.71), while knee sagittal-plane moments were the most consistent measure across sites (3-center mean CMC ≥.94).

CONCLUSIONS

CMC waveform comparisons were similar relative to the joint measured to previously published reports of between-sessions reliability of sagittal- and frontal-plane biomechanics performed at a single institution. Continued research is needed to further standardize technology and methods to help ensure that highly reliable results can be achieved with multicenter biomechanical screening models.

Для цитирования: Myer Gregory D, Bates Nathaniel A, DiCesare Christopher A, Barber Foss Kim D, Thomas Staci M, Wordeman Samuel C, Sugimoto Dai, Roewer Benjamin D, Medina McKeon Jennifer M, Di Stasi Stephanie L, Noehren Brian W, McNally Michael, Ford Kevin R, Kiefer Adam W, Hewett Timothy E. Reliability of 3-Dimensional Measures of Single-Leg Drop Landing Across 3 Institutions: Implications for Multicenter Research for Secondary ACL-Injury Prevention.. Journal of sport rehabilitation. 2015. DOI: 10.1123/jsr.2014-0237.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.