MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hansur.2021.12.001

Медицинская библиотека · Hand surgery & rehabilitation · 2021

Reduction in ionizing radiation exposure during minimally invasive anterior plate osteosynthesis of distal radius fracture: Naive versus deliberate practice.

Delbarre M, Hidalgo Diaz J J, Xavier F, Meyer N, Sapa M-C, Liverneaux P

СтатьяПеревод в очереди

Аннотация

This study aimed to decrease surgeon exposure to ionizing radiation through a new learning technique, "deliberate practice", which consists in improving performance by setting goals with feedback. The hypothesis was that exposure to ionizing radiation during distal radius fracture surgery using the minimally invasive plate osteosynthesis (MIPO) technique decreased faster with "deliberate" practice than with "naïve" practice. Radiographic dosimetry was measured in the first 30 fractures operated on by MIPO by 6 surgeons. The first 3 surgeons operated "naively" (Group 1) and the next 3 according to the "deliberate" procedure (Group 2). Group 2 received weekly feedback (number of exposed hands, number of fluoroscopic views, exposure duration, and X-ray dose). An expert, using fluoroscopic images and surgical videos, provided suggestions for improvement. Mean number of exposed hands was 23.66 in Group 1 and 1.9 in Group 2. Mean number of fluoroscopic views was 78.31 and 35.0, respectively. Mean X-ray exposure time was 74.34 and 32.89 s, respectively. Mean dosimetry was 1.40 mGy (and 0.59 mGy, respectively. The hypothesis was thus confirmed: dosimetry decreased faster in Group 2 than in Group 1. Teaching this deliberate practice should be generalized, to decrease the growth phase and increase the plateau phase of the learning curve.

Для цитирования: Delbarre M, Hidalgo Diaz J J, Xavier F, Meyer N, Sapa M-C, Liverneaux P. Reduction in ionizing radiation exposure during minimally invasive anterior plate osteosynthesis of distal radius fracture: Naive versus deliberate practice.. Hand surgery & rehabilitation. 2021. DOI: 10.1016/j.hansur.2021.12.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.